Design of a PV-Diesel Hybrid System with Unreliable Grid Connection in Lebanon
Högskolan Dalarna, Akademin Industri och samhälle, Energiteknik.
2016 (engelsk)Independent thesis Advanced level (degree of Master (Two Years)), 10 poäng / 15 hpOppgave
Abstract [en]

This thesis is a study on integration of photovoltaic generators into an existing diesel-unreliable grid connected system at the Lebanese village of Khiam. The main goal of implementing PV-diesel hybrid system is to reduce diesel consumption and the import of fossil fuel used in electricity power supply. Before designing the system, it is necessary to create a load profile for 120 households and pre-design the size of the PV generator, the capacity of storage system and inverter type/size selection. The load profile data is based on the average of monthly energy consumption gathered from Khiam village households.

Detailed simulations and financial analysis are performed with HOMER to compare different systems and their viability. The simulations include four different designs starting from the existing system, diesel generator with unreliable grid, followed by PV generator and unreliable grid, PV and diesel generator and ended with the complete hybrid system. Once the Hybrid system is determined a detailed design is done to optimize the lowest cost PV-diesel hybrid system. The final simulated PV-diesel hybrid system is suggested with a PV capacity of 270 kWp, existing diesel capacity with 200 kVA, an inverter output of 115 kW and battery bank nominal capacity is 1872 kWh. The system renewable fraction is 53% and the project life cycle is 25 years. The PV-diesel hybrid system is projected to produce electricity at a cost of 0.12 USD/kWh. This cost is significantly lower than the 0.26 USD/kWh paid to the diesel operator, as well as lower than 0.13 USD/kWh paid to the utility grid.

In addition, and according to the given information from the owner, an estimated diesel consumption of 104000 ltr/year, the simulation result shows diesel consumption at 40000 ltr/year. The reduced carbon dioxide production by 65%, from 776 to 272 tons per year, provides further justification for the PV installation in a commercial PV-diesel hybrid system.

sted, utgiver, år, opplag, sider
2016.
Emneord [en]
Battery, Diesel generator, Hybrid power system, HOMER, PV Modules, optimization of solar PV diesel hybrid system for residential loads.
HSV kategori
Identifikatorer
URN: urn:nbn:se:du-24465OAI: oai:DiVA.org:du-24465DiVA, id: diva2:1077879
Tilgjengelig fra: 2017-03-01 Laget: 2017-03-01 Sist oppdatert: 2017-03-01

Open Access i DiVA

fulltext(1932 kB)1762 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 1932 kBChecksum SHA-512
401cbcbc02a7cb3bf99426d4d3379174e263609343ddb989cbd27d16b05a0c104b4274effcb064084d695b5f56db41c05d92e9dcab54ee86d66dca6bf3ed8f23
Type fulltextMimetype application/pdf

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 1762 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 559 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf