Dalarna University's logo and link to the university's website

du.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Fallstudie av moderna timmerhus: Kvalitetskontroll av nybyggda timmerhus mot FST:s kvalitetsnormer och BBR:s kommande energihushållningskrav
Högskolan Dalarna, Akademin Industri och samhälle, Byggteknik.
Högskolan Dalarna, Akademin Industri och samhälle, Byggteknik.
2017 (svensk)Independent thesis Basic level (degree of Bachelor), 10 poäng / 15 hpOppgaveAlternativ tittel
Case study of modern log homes (engelsk)
Abstract [sv]

En studie har gjorts för att undersöka lufttätheten hos timmerhus tillverkade under senare tid och deras möjlighet att klara de nya kraven om U-värde och energianvändning med primärenergifaktor som grund, vilka kommer tas i bruk under 2017. Föreningen Svenska timmerhus har beställt studien. I studien har två hus i Dalarna undersökts. Båda husen var byggda med 200 mm blockat timmer efter de kvalitetsnormer som Föreningen Svenska Timmerhus rekommenderar. Båda husen har bergvärme som värmekälla. Studien kom fram till att de nya kraven kommer påverka timmerhuskonstruktioner negativt, förutsatt att uppvärmningssystemen är baserade på antingen bergvärme eller el, då en primärenergi tal på 1,6 kommer multipliceras med den totala energiförbrukningen vid uppvärmning med hjälp av el.

Abstract [en]

A study has been conducted to investigate how log houses will meet the new requirements regarding U-value and specific energy use with primary energy factor as a basis, which will be put into use in 2017. In the study, two houses have been investigated. Both houses were constructed with 200 mm thick logs without any additional isolation. Both houses have geothermal heating systems. The study found that the new requirements will be rough against timber house constructions with geothermal or electricity as a heating system, since a primary energy figure of 1.6 will be multiplied by the total energy consumption when heated by electricity.

sted, utgiver, år, opplag, sider
2017.
Emneord [en]
Log homes; Energy consumption; Air leakage
Emneord [sv]
Timmerhus; Energianvändning; Luftläckage
HSV kategori
Identifikatorer
URN: urn:nbn:se:du-27271OAI: oai:DiVA.org:du-27271DiVA, id: diva2:1184370
Tilgjengelig fra: 2018-02-21 Laget: 2018-02-21

Open Access i DiVA

Fulltekst mangler i DiVA

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric

urn-nbn
Totalt: 542 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf