Dalarna University's logo and link to the university's website

du.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Use of Solar Energy in Low Cost Housing in De Ar, South Africa
Högskolan Dalarna, Akademin Industri och samhälle, Miljöteknik.
2003 (engelsk)Independent thesis Advanced level (degree of Master (Two Years))Oppgave
Abstract [en]

The housing situation in South Africa needs serious improvement and intervention. There is a huge amount of housing backlog, and the living conditions, housing quality in low-income areas is beneath an acceptable level. The solution at present is considered to be large scale, low-cost housing projects, supported by governmental subsidies. Providing indoor comfort is a critical issue – the dwellers often don’t have proper means of heating during the cold winter period. Implementing solar energy might possibly be the solution to resolve this problem. This paper evaluates a design of a low-cost house that utilizes solar energy to provide indoor comfort. Evaluation is based on theoretical calculations, dynamic computer simulations, and on-site measurements and testing. The results show positive results. Theoretically the current design for a low-cost house working with solar technology functions sufficiently, even more so if the improvements recommended by this report will be implemented. It was found that factors having strong effect on system performance were: - the heat loss coefficient of the rockbed – installing heat insulation around the rockbed, thus reducing the heat loss coefficient from 11.35 kJ/hm2K to about 5 kJ/hm2K, the low values of indoor night temperatures can be increased from 14?C to about 18?C. - the flow rate of fluid circulating in the closed loop – by reducing the flowrate from 0.32 kg/s to 0.16 kg/s, the indoor temperatures during the night can be increased from 14?C to about 16.5?C. - by combining these improvements, a nighttime indoor temperature of about 22?C can be achieved. Further testing is required to confirm these presumptions, but until then this new, innovative design silution is deemed to be a successful trial in improving indoor comfort through utilizing solar technology.

sted, utgiver, år, opplag, sider
Borlänge, 2003. , s. 111
Identifikatorer
URN: urn:nbn:se:du-1367OAI: oai:dalea.du.se:1367DiVA, id: diva2:517867
Uppsök
Technology
Veileder
Tilgjengelig fra: 2005-08-12 Laget: 2005-08-12 Sist oppdatert: 2012-04-24bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric

urn-nbn
Totalt: 106 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf