Dalarna University's logo and link to the university's website

du.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Passive crosslaminated timber buildings: Final report Cerbof-project no. 76
Högskolan Dalarna, Akademin Industri och samhälle, Energi och miljöteknik. (Energi, skog och byggd miljö)
Högskolan Dalarna, Akademin Industri och samhälle, Byggteknik.
Högskolan Dalarna, Akademin Industri och samhälle, Byggteknik.
Vise andre og tillknytning
2013 (engelsk)Rapport (Annet vitenskapelig)
Abstract [en]

In this project, Stora Enso’s newly developed building system has been further developed to allow building to the Swedish passive house standard for the Swedish climate. The building system is based on a building framework of CLT (Cross laminated timber) boards. The concept has been tested on a small test building. The experience gained from this test building has also been used for planning a larger building (two storeys with the option of a third storey) with passive house standard with this building system.

The main conclusions from the project are:

 It is possible to build airtight buildings with this technique without using traditional vapour barriers. Initial measurements show that this can be done without reaching critical humidity levels in the walls and roof, at least where wood fibre insulation is used, as this has a greater capacity for storing and evening out the moisture than mineral wool. However, the test building has so far not been exposed to internal generation of moisture (added moisture from showers, food preparation etc.). This needs to be investigated and this will be done during the winter 2013-14.

 A new fixing method for doors and windows has been tested without traditional fibre filling between them and the CLT panel. The door or window is pressed directly on to the CLT panel instead, with an expandable sealing strip between them. This has been proved to be successful.

 The air tightness between the CLT panels is achieved with expandable sealing strips between the panels. The position of the sealing strips is important, both for the air tightness itself and to allow rational assembly.

 Recurrent air tightness measurements show that the air tightness decreased somewhat during the first six months, but not to such an extent that the passive house criteria were not fulfilled. The reason for the decreased air tightness is not clear, but can be due to small movements in the CLT construction and also to the sealing strips being affected by changing outdoor temperatures.

 Long term measurements (at least two years) have to be carried out before more reliable conclusions can be drawn regarding the long term effect of the construction on air tightness and humidity in the walls.

 An economic analysis comparing using a concrete frame or the studied CLT frame for a three storey building shows that it is probably more expensive to build with CLT. For buildings higher than three floors, the CLT frame has economic advantages, mainly because of the shorter building time compared to using concrete for the frame. In this analysis, no considerations have been taken to differences in the influence on the environment or the global climate between the two construction methods.

sted, utgiver, år, opplag, sider
Borlänge: Högskolan Dalarna, 2013. , s. 43
Serie
Centrum för solenergiforskning, Högskolan Dalarna, ISSN 1401-7555 ; 104
Emneord [en]
massivträ, passivhus
HSV kategori
Forskningsprogram
Forskningsprofiler 2009-2020, Energi och samhällsbyggnad
Identifikatorer
URN: urn:nbn:se:du-13667ISRN: DU-SERC—104—SEOAI: oai:DiVA.org:du-13667DiVA, id: diva2:693611
Forskningsfinansiär
Cerbof, 76Tilgjengelig fra: 2014-02-04 Laget: 2014-02-04 Sist oppdatert: 2021-11-12bibliografisk kontrollert

Open Access i DiVA

fulltext(4488 kB)8249 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 4488 kBChecksum SHA-512
8c32c1fdb7305d1e5ba8dcbb73193d9a235c6640cd99efe740f5e280501f1522773eee30b732e756f0179cb382237469c3d8b0b734de8d8bc6e2c13e382ffc0b
Type fulltextMimetype application/pdf

Søk i DiVA

Av forfatter/redaktør
Rönnelid, MatsWik, TinaJanols, Henrik
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 8252 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 1991 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf