du.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Weak light performance efficiency in installed pv-arrays of different module technologies
Högskolan Dalarna, Akademin Industri och samhälle, Energiteknik.ORCID-id: 0000-0001-6805-2112
Högskolan Dalarna, Akademin Industri och samhälle, Energiteknik.
juwi Solar GmbH.
2014 (engelsk)Inngår i: 29th European Photovoltaic Solar Energy Conference and Exhibition Proceedings, 2014, s. 2515-2522Konferansepaper, Oral presentation with published abstract (Annet vitenskapelig)
Abstract [en]

This work analyses the weak light performance efficiency of six different free field and grid-connected PVarrays of various module technologies (mc-Si, CIGS, CdTe). The installed capacities per array range from 1,8kWp to 2,2kWp. The studied systems are located at the same site in Germany and are mounted on a ventilated and shaded-free structure. The irradiance was measured with both a pyranometer and a c-Si reference cell oriented at the plane of the array. Besides the weather conditions, the arrays share a similar system configuration (same inverter model, rack type and orientation, temperature sensors, etc.) making their results highly comparable. The data collected comprised 312 days from September 2011 until July 2012. When analyzing the data points at moments of low irradiance (< 800W/m2), a high dispersion was found which is most likely due to optical effects, different spectral distributions and changing module temperatures. To reduce the optical and spectral effects, a series of data filters were applied to limit the points used (Air Mass ≤4 and Angle of Incidence ≤50°). To compensate for the temperature effects and translate the values to STC (25°C), five different methods were assessed. The Procedure 2 of the IEC 60891 was considered the most suitable due to its relative simplicity, availability of parameters in the datasheets, good accuracy even with missing values, and the potential to improve the results when the complete set of inputs is available. The final analysis of the weak light performance showed no clear superiority of any particular PV-technology. From the results of this study, an overall advantage of thin-film over crystalline modules cannot be anymore concluded.

sted, utgiver, år, opplag, sider
2014. s. 2515-2522
Emneord [en]
Weak light performance, PV-modules, Grid connected PV-plants
HSV kategori
Forskningsprogram
Energi, skog och byggd miljö
Identifikatorer
URN: urn:nbn:se:du-16432DOI: 10.4229/EUPVSEC20142014-5DO.12.2ISBN: 3-936338-34-5 (tryckt)OAI: oai:DiVA.org:du-16432DiVA, id: diva2:764940
Konferanse
29th European Photovoltaic Solar Energy Conference and Exhibition, Amsterdam, The Netherlands, 22 - 26 September 2014
Tilgjengelig fra: 2014-11-20 Laget: 2014-11-20 Sist oppdatert: 2016-05-03bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fullteksthttp://www.eupvsec-proceedings.com/proceedings?paper=28569

Personposter BETA

Hernandez Velasco, Marco

Søk i DiVA

Av forfatter/redaktør
Hernandez Velasco, MarcoFiedler, Frank
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetric

doi
isbn
urn-nbn
Totalt: 747 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf