Electrical Evaluation of a Low Concentrating PVT Collector Based on Performance Ratio
Högskolan Dalarna, Akademin Industri och samhälle, Energi och miljöteknik.
2015 (Engelska)Självständigt arbete på avancerad nivå (magisterexamen), 10 poäng / 15 hpStudentuppsats (Examensarbete)
Abstract [en]

Photovoltaic Thermal/Hybrid collectors are an emerging technology that combines PV

and solar thermal collectors by producing heat and electricity simultaneously. In this paper,

the electrical performance evaluation of a low concentrating PVT collector was done

through two testing parts: power comparison and performance ratio testing. For the

performance ratio testing, it is required to identify and measure the factors affecting the

performance ratio on a low concentrating PVT collector. Factors such as PV cell

configuration, collector acceptance angle, flow rate, tracking the sun, temperature

dependence and diffuse to irradiance ratio.

Solarus low concentrating PVT collector V12 was tested at Dalarna University in Sweden

using the electrical equipment at the solar laboratory. The PV testing has showed

differences between the two receivers. Back2 was producing 1.8 energy output more than

Back1 throughout the day. Front1 and Front2 were almost the same output performance.

Performance tests showed that the cell configuration for Receiver2 with cells grouping (6-

32-32-6) has proved to have a better performance ratio when to it comes to minimizing

the shading effect leading to more output power throughout the day because of lowering

the mismatch losses. Different factors were measured and presented in this thesis in

chapter 5.

With the current design, it has been obtained a peak power at STC of 107W per receiver.

The solar cells have an electrical efficiency of approximately 19% while the maximum

measured electrical efficiency for the collector was approximately 18 % per active cell area,

in addition to a temperature coefficient of -0.53%/ ˚C. Finally a recommendation was

done to help Solarus AB to know how much the electrical performance is affected during

variable ambient condition and be able to use the results for analyzing and introducing

new modification if needed.

Ort, förlag, år, upplaga, sidor
2015.
Nationell ämneskategori
Naturresursteknik
Identifikatorer
URN: urn:nbn:se:du-17007OAI: oai:DiVA.org:du-17007DiVA, id: diva2:790284
Tillgänglig från: 2015-02-24 Skapad: 2015-02-24 Senast uppdaterad: 2015-03-13Bibliografiskt granskad

Open Access i DiVA

fulltext(4233 kB)610 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 4233 kBChecksumma SHA-512
4fb383cf8e7e655eacc970eb7a71e7c70ff064efb25b13adf375f1f69ec2a02c2baed0819c325c53528a00db244cfa0c1ede1b8eb74ae6340dc68cf4db2d299d
Typ fulltextMimetyp application/pdf

Av organisationen
Energi och miljöteknik
Naturresursteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 610 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 1473 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf