Prediction of occupancy level and energy consumption in office building using blind system identification and neural networks
Visa övriga samt affilieringar
2019 (Engelska)Ingår i: Applied Energy, ISSN 0306-2619, E-ISSN 1872-9118, Vol. 240, s. 276-294Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Occupancy behaviour plays an important role in energy consumption in buildings. Currently, the shallow understanding of occupancy has led to a considerable performance gap between predicted and measured energy use. This paper presents an approach to estimate the occupancy based on blind system identification (BSI), and a prediction model of electricity consumption by an air-conditioning system is developed and reported based on an artificial neural network with the BSI estimation of the number of occupants as an input. This starts from the identification of indoor CO2 dynamics derived from the mass-conservation law and venting levels. The unknown parameters, including the occupancy and model parameters, are estimated by using a frequentist maximum-likelihood algorithm and Bayesian estimation. The second phase is to establish the prediction model of the electricity consumption of the air-conditioning system by using a feed-forward neural network (FFNN) and extreme learning machine (ELM), as well as ensemble models. To analyse some aspects of the benchmark test for identifying the effect of structure parameters and input-selection alternatives, three studies are conducted on (1) the effect of predictor selection based on principal component analysis, (2) the effect of the estimated occupancy as the supplementary input, and (3) the effect of the neural network ensemble. The result shows that the occupancy number, as the input, is able to improve the accuracy in predicting energy consumption using a neural network model.

Ort, förlag, år, upplaga, sidor
Elsevier, 2019. Vol. 240, s. 276-294
Nyckelord [en]
Occupancy estimation; Blind system identification (BSI); Prediction model for energy consumption; Feedforward neural network; Extreme learning machine
Nationell ämneskategori
Energiteknik
Forskningsämne
Energi och samhällsbyggnad
Identifikatorer
URN: urn:nbn:se:du-29562DOI: 10.1016/j.apenergy.2019.02.056ISI: 000468714300020OAI: oai:DiVA.org:du-29562DiVA, id: diva2:1291293
Tillgänglig från: 2019-02-24 Skapad: 2019-02-24 Senast uppdaterad: 2020-02-03Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Personposter BETA

Zhang, XingxingHan, Mengjie

Sök vidare i DiVA

Av författaren/redaktören
Zhang, XingxingHan, Mengjie
Av organisationen
EnergiteknikMikrodataanalys
I samma tidskrift
Applied Energy
Energiteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 40 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf