Evaluation of Monitored Pellet & Solar Heating Systems
Högskolan Dalarna, Akademin Industri och samhälle, Energi och miljöteknik.
2009 (Engelska)Självständigt arbete på avancerad nivå (masterexamen)Studentuppsats (Examensarbete)
Abstract [en]

In this study, three solar and pellet heating systems have been studied with the help of monitoring system. The main technology of these three systems is generally the same. The main target system is located in Hedemora which has an extra shunt loop in the boiler circuit. The following data have been monitored during this period: the solar irradiation, the outdoor and indoor temperature, the return and supply temperature of each circuit, the flow rate of each loop, the 3-phase and 1-phase electricity consumption. The aim of this thesis work is to evaluate the thermal performance of the system and through analysis of the detailed data find whether each component of the system functions as it should do. Also the main ambition is to make some improvements based on analysis of the one minute step monitoring data. The whole system can be divided into four different circuits: solar collector circuit, DHW circuit, space heating circuit and boiler circuit. In the process of study, a special excel sheet should be used to calculate the energy balance and operational curve of each component. In general, we found that the monitoring result varies with design setting. And more heat losses have been found in the process of the operating. For a two person detached house, ten square meter solar collector and 750 litres buffer store are both oversized. Based on these findings, in the future work, more simulations are needed. To pursuit more efficiency thermal performance, some temperature setting of the control system should be changed.

Ort, förlag, år, upplaga, sidor
Borlänge, 2009. , s. 46
Identifikatorer
URN: urn:nbn:se:du-4618OAI: oai:dalea.du.se:4618DiVA, id: diva2:518811
Uppsök
teknik
Handledare
Tillgänglig från: 2010-03-29 Skapad: 2010-03-29 Senast uppdaterad: 2012-04-24Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Av organisationen
Energi och miljöteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 17 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf