Design considerations with ventilation-radiators: Comparisons to traditional two-panel radiators
Department of Fluid and Climate Technology, School of Technology and Health, KTH, Alfred Nobels Allé 10, SE-14152 Huddinge, Stockholm, Sweden. (Energi, skog och byggd miljö)ORCID-id: 0000-0002-9943-9878
Department of Fluid and Climate Technology, School of Technology and Health, KTH, Alfred Nobels Allé 10, SE-14152 Huddinge, Stockholm, Sweden.
2009 (Engelska)Ingår i: Energy and Buildings, ISSN 0378-7788, Vol. 41, nr 1, 92-100 s.Artikel i tidskrift (Refereegranskat) Published
Ort, förlag, år, upplaga, sidor
Elsevier, 2009. Vol. 41, nr 1, 92-100 s.
Nationell ämneskategori
Naturvetenskap Husbyggnad
Identifikatorer
URN: urn:nbn:se:du-14190DOI: 10.1016/j.enbuild.2008.07.014ISI: 000261483800011OAI: oai:DiVA.org:du-14190DiVA: diva2:722980
Forskningsfinansiär
Energimyndigheten, 30326-1
Anmärkning

Performance of heat emitters in a room is affected by their interaction with the ventilation system. A radiator gives more heat output with increased air flow along its heat transferring surface, and with increased thermal difference to surrounding air. Radiator heat output and comfort temperatures in a small one-person office were studied using different positions for the ventilation air inlet. In two of the four test cases the air inlet was placed between radiator panels to form ventilation-radiator systems. Investigations were made by CFD (Computational Fluid Dynamics) simulations, and included visualisation of thermal comfort conditions, as well as radiator heat output comparisons. The room model was exhaust-ventilated, with an air exchange rate equal to what is recommended for Swedish offices (7 l s1 per person) and cold infiltration air (5 8C) typical of a winter day in Stockholm.

Results showed that under these conditions ventilation-radiators were able to create a more stable thermal climate than the traditional radiator ventilation arrangements. In addition, when using ventilation-radiators the desired thermal climate could be achieved with a radiator surface temperature as much as 7.8C lower. It was concluded that in exhaust-ventilated office rooms, ventilation-radiators can provide energy and environmental savings.

Tillgänglig från: 2014-06-10 Skapad: 2014-06-10 Senast uppdaterad: 2015-10-23Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas

Övriga länkar

Förlagets fulltext

Sök vidare i DiVA

Av författaren/redaktören
Myhren, Jonn Are
I samma tidskrift
Energy and Buildings
NaturvetenskapHusbyggnad

Sök vidare utanför DiVA

GoogleGoogle Scholar

Altmetricpoäng

Totalt: 482 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf