Assessment of the potential for district heating to lower the peak electricity consumption in a medium size municipality in Sweden
Högskolan Dalarna, Akademin Industri och samhälle, Energiteknik. Mälardalen University.ORCID-id: 0000-0002-3630-663X
Högskolan Dalarna, Akademin Industri och samhälle, Byggteknik.ORCID-id: 0000-0002-9943-9878
Mälardalen University.
(engelsk)Manuskript (preprint) (Annet vitenskapelig)
Abstract [en]

Sweden faces several challenges when more intermittent renewable power is integrated into the energy system. One of the challenges is to have enough electrical power available in periods with low production from intermittent sources. A solution to the problem could be to reduce the electricity peak demand and at the same time produce more electricity during peak hours. One way of doing this is to convert electricity based heating in buildings to district heating (DH) based on combined heat and power (CHP).

The study analyzes how much a medium sized Swedish municipality can contribute to lower the electricity peak demand. This is done by quantifying the potential to reduce the peak demand for six different scenarios of the future heat market volume and heat market shares regarding electricity based heating and DH in 2050.

The main finding is that electricity consumption will be reduced by 35-70 % during the peak hour (and 20-40 % on a yearly basis) for all the six scenarios studied compared with the current situation. If the aim is to lower the electricity peak demand in the future, the choice of heating system is more important than reducing the heat demand itself. For the scenario with a large share of DH, it is possible to cover the electricity peak demand in the municipality by using CHP.

HSV kategori
Forskningsprogram
Energi, skog och byggd miljö
Identifikatorer
URN: urn:nbn:se:du-23585OAI: oai:DiVA.org:du-23585DiVA, id: diva2:1056739
Tilgjengelig fra: 2016-12-15 Laget: 2016-12-15 Sist oppdatert: 2016-12-16bibliografisk kontrollert
Inngår i avhandling
1. The impact on the energy system of heating demands in buildings: A case study on district heating and electricity for heating in Falun, Sweden
Åpne denne publikasjonen i ny fane eller vindu >>The impact on the energy system of heating demands in buildings: A case study on district heating and electricity for heating in Falun, Sweden
2017 (engelsk)Licentiatavhandling, med artikler (Annet vitenskapelig)
Abstract [en]

Energy efficiency measures in buildings are considered to have great potential in order to reduce total energy consumption, and thus contribute to a reduced environmental impact and a better climate. In Sweden, however, the energy performance requirements for buildings are formulated in terms of bought energy, i.e. as bought electricity and district heating (DH), which does not always reflect the environmental and climate impact from a broader perspective. Focusing on bought energy means that many choose an electricity-based heat pump solution in their building instead of DH, since heat pumps result in a smaller amount of bought energy compared to DH.

The surrounding energy system of the buildings is affected by the choice of energy carriers used for heating. How the energy system is affected is studied in this thesis using two different methods. In the first part, primary energy consumption has been calculated for a simulated building with different heating solutions, representing different electricity and DH demands. In the second part, the impact on total consumption in the surrounding power and DH networks due to different market shares of electricity-based heating and DH has been studied. The second part also includes an analysis of the potential to produce electricity using combined heat and power (CHP) in different scenarios depending on the market share of DH. This part has been carried out as a case study for the Swedish municipality of Falun.

The results show that the choice of energy carrier has a great influence on primary energy consumption. The resulting primary energy consumption does, however, to an even greater extent depend on the calculation method used. Which heating solution, and thus also which energy carrier, gets the lowest primary energy consumption varies in the different methods.

The surrounding power and DH networks are also affected to a great extent by the choice of energy carrier. There is a huge potential to lower peak demand in the power grid by avoiding electricity-based heating. The potential to produce electricity using CHP is also increased with a larger market share for DH. In Falun, reduced electricity demand and increased electricity production using CHP make it possible to cover the peak power demand using only electricity production from CHP. In comparison, 10 % of the peak power demand was covered by electricity from CHP in 2015.

The choice of energy carrier for heating in buildings affects the surrounding energy system to a high degree, and is therefore an important aspect to take into account in both local, national and global energy efficiency projects. 

sted, utgiver, år, opplag, sider
Västerås: Mälardalen university press, 2017
Serie
Mälardalen University Press Licentiate Theses, ISSN 1651-9256 ; 250
HSV kategori
Forskningsprogram
Energi, skog och byggd miljö
Identifikatorer
urn:nbn:se:du-23593 (URN)978-91-7485-305-6 (ISBN)
Forskningsfinansiär
Knowledge Foundation
Tilgjengelig fra: 2016-12-16 Laget: 2016-12-15 Sist oppdatert: 2016-12-16bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Personposter BETA

Swing Gustafsson, MoaMyhren, Jonn Are

Søk i DiVA

Av forfatter/redaktør
Swing Gustafsson, MoaMyhren, Jonn Are
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric

urn-nbn
Totalt: 229 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf