Experimental investigations of polymer hollow fibre integrated evaporative cooling system with the fibre bundles in a spindle shape
Högskolan Dalarna, Akademin Industri och samhälle, Energiteknik.ORCID-id: 0000-0002-2369-0169
Vise andre og tillknytning
2017 (engelsk)Inngår i: Energy and Buildings, ISSN 0378-7788, E-ISSN 1872-6178, Vol. 154, s. 166-174Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Due to the advantages of light weight, corrosion resistant and low cost, hollow fibres have been studied as the substitute for metallic materials. A novel hollow fibre integrated evaporative cooling system, in which the hollow fibre module constitutes as the humidifier and the evaporative cooler, is proposed. This novel hollow fibre integrated evaporative cooling system will provide a comfortable indoor environment for hot and dry area. Moreover, the water vapour can permeate through the hollow fibre effectively, and the liquid water droplets will be prevented from mixing with the processed air. In order to avoid the flow channelling or shielding of adjacent fibres, the fibres inside each bundle were made into a spindle shape to allow maximum contact between the air stream and the fibre. The cooling performances of the proposed novel polymer hollow fibre integrated evaporative cooling system were experimentally investigated under the incoming air temperature in the range of 26 °C to 32 °C and relative humidity of 25%–35%. The effects of air velocities on the cooling effectiveness, heat and mass transfer coefficients, specific water consumption and pressure drop across the polymer hollow fibre module were analysed. Two sets of experimentally derived non-dimensional heat and mass transfer correlations were summarized, which could be favourable for the future design of polymer hollow fibre integrated evaporative cooling system.

sted, utgiver, år, opplag, sider
2017. Vol. 154, s. 166-174
Emneord [en]
Evaporative cooling, Experiment, Heat transfer, Mass transfer, Polymer hollow fibre
HSV kategori
Forskningsprogram
Energi, skog och byggd miljö
Identifikatorer
URN: urn:nbn:se:du-26295DOI: 10.1016/j.enbuild.2017.08.068ISI: 000413607400014Scopus ID: 2-s2.0-85028703256OAI: oai:DiVA.org:du-26295DiVA, id: diva2:1142097
Tilgjengelig fra: 2017-09-18 Laget: 2017-09-18 Sist oppdatert: 2017-11-09bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Personposter BETA

Zhang, Xingxing

Søk i DiVA

Av forfatter/redaktør
Zhang, Xingxing
Av organisasjonen
I samme tidsskrift
Energy and Buildings

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 145 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf