du.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Experimental investigation of a polymer hollow fibre integrated liquid desiccant dehumidification system with aqueous potassium formate solution
Vise andre og tillknytning
2018 (engelsk)Inngår i: Applied Thermal Engineering, ISSN 1359-4311, E-ISSN 1873-5606, Vol. 142Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Hollow fibres have been studied as the substitute for metallic materials due to the advantages such as light weight, corrosion resistant and low cost in heat and mass transfer applications. A novel polymer hollow fibre liquid desiccant dehumidification system, in which a cross-flow hollow fibre module (fibre inside diameter=1.4mm) serves as the dehumidifier, is presented in this paper. This novel hollow fibre integrated liquid desiccant dehumidification system can be used in an air conditioning system to provide a comfortable indoor environment for hot and humid area. Compared with other conventional liquid desiccant dehumidifier, the polymer hollow fibre has a very small diameter which leads to significantly increased surface area. Moreover, the porous feature of the hollow fibre module can help to eliminate any liquid desiccant droplets carryover into the process air. As a less corrosive and more environmental friendly working fluid, aqueous potassium formate (KCOOH) solution has been selected. The dehumidification performance of the proposed system were analysed experimentally under the conditions of incoming air temperature in the range of 30°C to 45°C. The variations of dehumidification sensible and latent effectiveness, moisture removal rates were studied by varying the incoming air velocity from 0.65 m/s to 4.5m/s. With the various values of incoming air relative humidity in the range of 55% to 75% and the solution concentrations between 36% and 62%, the experimental obtained latent effectiveness are in the range of 0.25 to 0.43 and the sensible effectiveness are in the range of 0.31 to 0.52, which is in a satisfactory agreement with the empirical correlation of effectiveness-NTU in the literature.

sted, utgiver, år, opplag, sider
2018. Vol. 142
Emneord [en]
Polymer hollow fibreliquid desiccant dehumidificationheat transfermass transferexperiment
HSV kategori
Forskningsprogram
Energi, skog och byggd miljö
Identifikatorer
URN: urn:nbn:se:du-28106DOI: 10.1016/j.applthermaleng.2018.07.003ISI: 000443663300057OAI: oai:DiVA.org:du-28106DiVA, id: diva2:1230591
Tilgjengelig fra: 2018-07-04 Laget: 2018-07-04 Sist oppdatert: 2018-09-24bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Personposter BETA

Zhang, Xingxing

Søk i DiVA

Av forfatter/redaktør
Zhang, Xingxing
Av organisasjonen
I samme tidsskrift
Applied Thermal Engineering

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 90 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf