Study of optimal sizing for residential sorption heat pump system
Högskolan Dalarna, Akademin Industri och samhälle, Energiteknik. SaltX Technology, Hägersten, Stockholm; Mälardalen University. (REESBE)
2019 (engelsk)Inngår i: Applied Thermal Engineering, ISSN 1359-4311, E-ISSN 1873-5606, Vol. 150, nr 5, s. 421-432Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Gas-driven sorption heat pumps (GDSHP) show significant potential to reduce primary energy use, associated emissions and energy costs for space heating and domestic hot water production in residential applications. This study considered a bivalent heating system consisting of a sorption heat pump and a condensing boiler, and focuses on the optimal heating capacity of each of these components relative to each other. Two bivalent systems were considered: one based on a solid chemisorption cycle (GDSHPA), and one based on a resorption cycle (GDSHPB). Simulations of year-round space heating loads for two single family houses, one in New York and the other Minnesota, were carried out and the seasonal gas coefficient of performance (SGCOP) calculated. The sorption heat pump’s design heating capacity as a fraction of the bivalent system’s total heating capacity was varied from 0 to 100%. Results show that SGCOP was effectively constant for sorption heat pump design capacity greater than 41% of the peak bivalent GDSHPA design capacity in Minnesota, and 32% for GDSHPB. In New York, these values were 42% and 34% for GDSHPA and GDSHPB respectively. Payback period was also evaluated based on postulated sorption heat pump component costs. The fastest payback was achieved with sorption heat pump design capacity between 22–44%.

sted, utgiver, år, opplag, sider
2019. Vol. 150, nr 5, s. 421-432
Emneord [en]
Sorption heat pump, sizing, residential, bivalent
HSV kategori
Forskningsprogram
Energi och samhällsbyggnad
Identifikatorer
URN: urn:nbn:se:du-29258DOI: 10.1016/j.applthermaleng.2018.12.151ISI: 000462418200037Scopus ID: 2-s2.0-85059855024OAI: oai:DiVA.org:du-29258DiVA, id: diva2:1276030
Tilgjengelig fra: 2019-01-07 Laget: 2019-01-07 Sist oppdatert: 2019-04-11bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Personposter BETA

Blackman, Corey

Søk i DiVA

Av forfatter/redaktør
Blackman, Corey
Av organisasjonen
I samme tidsskrift
Applied Thermal Engineering

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 162 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf