du.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Scaling of upper-body power output to predict time-trial roller skiing performance
Högskolan Dalarna, Akademin Utbildning, hälsa och samhälle, Idrotts- och hälsovetenskap.ORCID-id: 0000-0002-7178-5357
Högskolan Dalarna, Akademin Utbildning, hälsa och samhälle, Idrotts- och hälsovetenskap.
Högskolan Dalarna, Akademin Utbildning, hälsa och samhälle, Idrotts- och hälsovetenskap.ORCID-id: 0000-0001-8360-2100
Umeå Universitet, Idrottsmedicin.
Vise andre og tillknytning
2013 (engelsk)Inngår i: Journal of Sports Sciences, ISSN 0264-0414, E-ISSN 1466-447X, Vol. 31, nr 6, s. 582-588Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The purpose of the present study was to establish the most appropriate allometric model to predict mean skiing speed during a double-poling roller skiing time-trial using scaling of upper-body power output. Forty-five Swedish junior cross-country skiers (27 men and 18 women) of national and international standard were examined. The skiers, who had a body mass (m) of 69.3 ± 8.0 kg (mean ± s), completed a 120-s double-poling test on a ski ergometer to determine their mean upper-body power output (W). Performance data were subsequently obtained from a 2-km time-trial, using the double-poling technique, to establish mean roller skiing speed. A proportional allometric model was used to predict skiing speed. The optimal model was found to be: Skiing speed = 1.057 · W 0.556 · m −0.315, which explained 58.8% of the variance in mean skiing speed (P < 0.001). The 95% confidence intervals for the scaling factors ranged from 0.391 to 0.721 for W and from −0.626 to −0.004 for m. The results in this study suggest that allometric scaling of upper-body power output is preferable for the prediction of performance of junior cross-country skiers rather than absolute expression or simple ratio-standard scaling of upper-body power output.

sted, utgiver, år, opplag, sider
Taylor & Francis, 2013. Vol. 31, nr 6, s. 582-588
Emneord [en]
cross-country skiing, double-poling, body mass, testing
HSV kategori
Forskningsprogram
Hälsa och välfärd
Identifikatorer
URN: urn:nbn:se:du-11303DOI: 10.1080/02640414.2012.744079ISI: 000316216800002OAI: oai:DiVA.org:du-11303DiVA, id: diva2:571389
Tilgjengelig fra: 2012-11-22 Laget: 2012-11-22 Sist oppdatert: 2017-12-07bibliografisk kontrollert
Inngår i avhandling
1. The importance of body-mass exponent optimization for evaluation of performance capability in cross-country skiing
Åpne denne publikasjonen i ny fane eller vindu >>The importance of body-mass exponent optimization for evaluation of performance capability in cross-country skiing
2015 (engelsk)Doktoravhandling, med artikler (Annet vitenskapelig)
Abstract [en]

Introduction Performance in cross-country skiing is influenced by the skier’s ability to continuously produce propelling forces and force magnitude in relation to the net external forces. A surrogate indicator of the “power supply” in cross-country skiing would be a physiological variable that reflects an important performance-related capability, whereas the body mass itself is an indicator of the “power demand” experienced by the skier. To adequately evaluate an elite skier’s performance capability, it is essential to establish the optimal ratio between the physiological variable and body mass. The overall aim of this doctoral thesis was to investigate the importance of body-mass exponent optimization for the evaluation of performance capability in cross-country skiing.

Methods In total, 83 elite cross-country skiers (56 men and 27 women) volunteered to participate in the four studies. The physiological variables of maximal oxygen uptake (V̇O2max) and oxygen uptake corresponding to a blood-lactate concentration of 4 mmol∙l-1 (V̇O2obla) were determined while treadmill roller skiing using the diagonal-stride technique; mean oxygen uptake (V̇O2dp) and upper-body power output () were determined during double-poling tests using a ski-ergometer. Competitive performance data for elite male skiers were collected from two 15-km classical-technique skiing competitions and a 1.25-km sprint prologue; additionally, a 2-km double-poling roller-skiing time trial using the double-poling technique was used as an indicator of upper-body performance capability among elite male and female junior skiers. Power-function modelling was used to explain the race and time-trial speeds based on the physiological variables and body mass.

Results The optimal V̇O2max-to-mass ratios to explain 15-km race speed were V̇O2max divided by body mass raised to the 0.48 and 0.53 power, and these models explained 68% and 69% of the variance in mean skiing speed, respectively; moreover, the 95% confidence intervals (CI) for the body-mass exponents did not include either 0 or 1. For the modelling of race speed in the sprint prologue, body mass failed to contribute to the models based on V̇O2max, V̇O2obla, and V̇O2dp. The upper-body power output-to-body mass ratio that optimally explained time-trial speed was m-0.57 and the model explained 63% of the variance in speed.

Conclusions The results in this thesis suggest that V̇O2max divided by the square root of body mass should be used as an indicator of performance in 15-km classical-technique races among elite male skiers rather than the absolute or simple ratio-standard scaled expression. To optimally explain an elite male skier’s performance capability in sprint prologues, power-function models based on oxygen-uptake variables expressed absolutely are recommended. Moreover, to evaluate elite junior skiers’ performance capabilities in 2-km double-poling roller-skiing time trials, it is recommended that divided by the square root of body mass should be used rather than absolute or simple ratio-standard scaled expression of power output.

sted, utgiver, år, opplag, sider
Umeå: Umeå University, 2015. s. 58
Serie
Umeå University medical dissertations, ISSN 0346-6612 ; 1712
Emneord
allometric scaling, power-function modelling, maximal oxygen uptake, body mass, elite skiers, distance skiing, lactate threshold, double poling, sprint skiing, competition, power output, time trial
HSV kategori
Forskningsprogram
Hälsa och välfärd
Identifikatorer
urn:nbn:se:du-20471 (URN)978-91-7601-270-3 (ISBN)
Disputas
2015-06-05, Föreläsningssal 6, Högskolegatan 2, 791 88, 14:00 (svensk)
Opponent
Veileder
Merknad

Incorrect ISBN in printed thesis: 973-91-7601-270-3

Tilgjengelig fra: 2015-12-21 Laget: 2015-12-21 Sist oppdatert: 2017-10-12bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Personposter BETA

Carlsson, TomasHammarström, Daniel

Søk i DiVA

Av forfatter/redaktør
Carlsson, TomasCarlsson, MagnusHammarström, DanielTonkonogi, Michail
Av organisasjonen
I samme tidsskrift
Journal of Sports Sciences

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 769 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf