Dalarna University's logo and link to the university's website

du.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Kiselhaltens inverkan på slagsegheten hos Charpy-V och oanvisad slagseghetsprovning: Slagseghetsprovning vid rumstemperatur, godstjocklek 150 mm
Dalarna University, School of Technology and Business Studies, Materials Technology.
2014 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
Effect of the silicon content on the impact toughness of Charpy V andun-notched impact testing (English)
Abstract [sv]

Examensarbetet bygger på en undersökning av två segjärn med olika kiselhalt. Undersökningen ska ge en djupare förståelse om hur resultaten från slagprovning av de två materialtyperna skiljer sig från varandra, och hur väl de båda provstavstyperna kan spegla den ändring i mikrostrukturen som borde bli resultatet av varierad kiselhalt. Ett gjutgods av trappliknade form har gjutits för de båda segjärnen. Med en kärnborr borrades provstavar ut från två godstjocklekar och bearbetades. Dessa prover blev till hälften vardera Charpy-V och oanvisade provstavar. Provstavarna delades in i åtta provserier. Proverna användes till slagprovning och data sammanställdes.  Strukturundersökningar har gjorts i svepelektronmikroskop, SEM och ljusmikroskop, LOM och hårdhetsprovning genom mikrovikers. Materialen skiljer sig på så sätt att materialet med det med lägre kiselhalt innehåller mer grafitmoduler, har högre slagseghetsvärden och är mjukare än högkiselmaterialet. Detta beror på att perliten har en kraftigare påverkan på slagseghet i EN-GJS-400-18. Dessutom har EN-GJS-400-18 grövre grafitpartiklar. Då både perliten och grafiten riskerar att ha en något ojämn fördelning i grundmassan kommer spridningen vid slagseghetsprovningen att sprida relativt mycket. Vad gäller den lägre slagsegheten hos EN-GJS-500-14 så kan den förmodligen förklaras av den högre hårdheten i grundmassan till följd av kislets lösningshärdande effekt på grundmassan. Den högre hårdheten påverkar slagsegheten negativt.

Abstract [en]

The thesis is based on a survey of two ductile iron with different silicon content. The study will provide a deeper understanding of how the results of the impact test of the two material types differ from each other, and how well the two specimen types may reflect the change in the microstructure that should be the result of varied silicon content.  A cast of stair similar form has been cast for the two ductile irons. With a core drilling were drilled to test pieces from two thicknesses and processed. These samples were half each Charpy-V and un-notched test bars. The specimens were divided into eight test series. The samples were used for impact testing and data was compiled. Structural studies have been done in a scanning electron microscope, SEM and light microscopy, LOM and hardness testing by mikrovikers. The materials differ in that the material with the lower silicon content of more graphite modules, has higher impact strength values and are softer than the material with higher silicon content. This is because the perlite has a stronger influence on the impact strength of EN-GJS-400-18. In addition, EN-GJS-400-18 has larger graphite particles. As both pearlite and graphite is likely to have a slightly uneven distribution in the matrix, this will result in a greater spread on the impact strength test values. As for the lower impact strength of EN-GJS-500-14, it can probably be explained by the higher hardness in the matrix due to the silicon solution hardening effect on the matrix. The higher hardness affects the impact strength negatively.

Place, publisher, year, edition, pages
2014.
Keywords [en]
Impact strength, toughness, ductility, Charpy V, un-notched impact testing, Scanning Electron Microscope (SEM).
Keywords [sv]
Slagseghet, seghet, duktilitet, slagseghetsprovning, Charpy-V, onotchad provning, Svepelektronmikroskop (SEM).
National Category
Materials Engineering
Identifiers
URN: urn:nbn:se:du-14637OAI: oai:DiVA.org:du-14637DiVA, id: diva2:732191
Available from: 2014-07-03 Created: 2014-07-03 Last updated: 2014-07-03Bibliographically approved

Open Access in DiVA

No full text in DiVA

By organisation
Materials Technology
Materials Engineering

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 527 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf