du.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Seated Double-Poling Ergometer Performance of Individuals with Spinal Cord Injury - A New Ergometer Concept for Standardized Upper Body Exercise
Gymnastik- och idrottshögskolan, GIH, Laboratoriet för biomekanik och motorisk kontroll (BMC).
Gymnastik- och idrottshögskolan, GIH, Laboratoriet för biomekanik och motorisk kontroll (BMC).
Gymnastik- och idrottshögskolan, GIH, Laboratoriet för tillämpad idrottsvetenskap (LTIV).
Gymnastik- och idrottshögskolan, GIH, Laboratoriet för biomekanik och motorisk kontroll (BMC).
2013 (engelsk)Inngår i: International Journal of Sports Medicine, ISSN 0172-4622, E-ISSN 1439-3964, Vol. 34, nr 2, s. 176-182Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

This study aimed to evaluate biomechanics during seated double-poling exercises in individuals with spinal cord injury (SCI) and to compare these with those of able-bodied persons (AB). 26 participants volunteered for the study; 13 with SCI (injury levels C7-T12), and 13 AB. A seated double-poling ergometer (SDPE) was developed. 3-dimensional kinematics was measured and piezoelectric force sensors were used to register force in both poles for calculation of power during incremental intensities. Significantly lower power outputs, (143.2 ± 51.1 vs. 198.3 ± 74.9 W) and pole forces (137.1 ± 43.1 vs. 238.2 ± 81.2 N) were observed during maximal effort in SCI compared to AB. Sagittal upper trunk range of motion increased with intensity and ranged from 6.1–34.8 ° for SCI, and 6.9–31.3 ° for AB, with larger peak amplitudes in flexion for AB (31.4 ± 12.9 °) compared to SCI (10.0 ± 8.0 °). All subjects with SCI were able to exercise on the SDPE. Upper body kinematics, power and force outputs increased with intensity in both groups, but were in general, lower in SCI. In conclusion, the SDPE could be successfully used at low to high work intensities enabling both endurance and strength training for individuals with SCI.

sted, utgiver, år, opplag, sider
Georg Thieme Verlag KG, 2013. Vol. 34, nr 2, s. 176-182
Emneord [en]
training, paraplegia, tetraplegia, ergometer, force, kinematics
HSV kategori
Identifikatorer
URN: urn:nbn:se:du-15643DOI: 10.1055/s-0032-1311653ISI: 000313908300013PubMedID: 22972247OAI: oai:DiVA.org:du-15643DiVA, id: diva2:747592
Tilgjengelig fra: 2012-10-22 Laget: 2014-09-16 Sist oppdatert: 2017-12-05bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMed

Søk i DiVA

Av forfatter/redaktør
Nilsson, Johnny
I samme tidsskrift
International Journal of Sports Medicine

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 494 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf