Electrical Evaluation of a Low Concentrating PVT Collector Based on Performance Ratio
Högskolan Dalarna, Akademin Industri och samhälle, Energi och miljöteknik.
2015 (engelsk)Independent thesis Advanced level (degree of Master (One Year)), 10 poäng / 15 hpOppgave
Abstract [en]

Photovoltaic Thermal/Hybrid collectors are an emerging technology that combines PV

and solar thermal collectors by producing heat and electricity simultaneously. In this paper,

the electrical performance evaluation of a low concentrating PVT collector was done

through two testing parts: power comparison and performance ratio testing. For the

performance ratio testing, it is required to identify and measure the factors affecting the

performance ratio on a low concentrating PVT collector. Factors such as PV cell

configuration, collector acceptance angle, flow rate, tracking the sun, temperature

dependence and diffuse to irradiance ratio.

Solarus low concentrating PVT collector V12 was tested at Dalarna University in Sweden

using the electrical equipment at the solar laboratory. The PV testing has showed

differences between the two receivers. Back2 was producing 1.8 energy output more than

Back1 throughout the day. Front1 and Front2 were almost the same output performance.

Performance tests showed that the cell configuration for Receiver2 with cells grouping (6-

32-32-6) has proved to have a better performance ratio when to it comes to minimizing

the shading effect leading to more output power throughout the day because of lowering

the mismatch losses. Different factors were measured and presented in this thesis in

chapter 5.

With the current design, it has been obtained a peak power at STC of 107W per receiver.

The solar cells have an electrical efficiency of approximately 19% while the maximum

measured electrical efficiency for the collector was approximately 18 % per active cell area,

in addition to a temperature coefficient of -0.53%/ ˚C. Finally a recommendation was

done to help Solarus AB to know how much the electrical performance is affected during

variable ambient condition and be able to use the results for analyzing and introducing

new modification if needed.

sted, utgiver, år, opplag, sider
2015.
HSV kategori
Identifikatorer
URN: urn:nbn:se:du-17007OAI: oai:DiVA.org:du-17007DiVA, id: diva2:790284
Tilgjengelig fra: 2015-02-24 Laget: 2015-02-24 Sist oppdatert: 2015-03-13bibliografisk kontrollert

Open Access i DiVA

fulltext(4233 kB)610 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 4233 kBChecksum SHA-512
4fb383cf8e7e655eacc970eb7a71e7c70ff064efb25b13adf375f1f69ec2a02c2baed0819c325c53528a00db244cfa0c1ede1b8eb74ae6340dc68cf4db2d299d
Type fulltextMimetype application/pdf

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 610 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 1473 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf