Dalarna University's logo and link to the university's website

du.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Lipton - Det smarta trähuset: Energieffektivisering av Dalahus lägenhetskomplex i trä
Högskolan Dalarna, Akademin Industri och samhälle, Byggteknik.
Högskolan Dalarna, Akademin Industri och samhälle, Byggteknik.
2015 (svensk)Independent thesis Basic level (university diploma), 10 poäng / 15 hpOppgaveAlternativ tittel
Lipton - The smart wooden house : Energy efficiency of Dalahus apartment complex in wood (engelsk)
Abstract [sv]

Jordens klimat påverkar alla länder och Sverige är inget undantag. Med ettväxande globalt miljöproblem måste alla hjälpas åt att bidra till ändring.Projektets bidrag till miljön är att visa hur energianvändningen för ettflerbostadshus kan reduceras. Detta görs genom att Beräkna Um för husetLiptons nuvarande klimatskal och identifiera de detaljer där förbättringar bordekunna göras, och sammanställa de konstruktionselement som verkar mestlovande för att förbättra klimatskalet. Även tekniska åtgärder som inte direktberör klimatskalet så som behovsstyrd ventilation, eleffektiva fläktar och andraenergismarta lösningar kommer att tas i anspråk för att reducera Liptonsspecifika energianvändning.Byggnader förlorar värme genom klimatskalet men genom att utnyttja solensenergi, noga tänka igenom byggnadens placering, öka isoleringstjockleken samtatt använda smarta ventilationslösningar är projektets mål att huset Liptonsspecifika energianvändning skall reduceras till minst hälften av Boverketsenergikrav 2014 för nybyggnationer i klimatzon 2 som är satt till 110 kWh/m2 år.För att beräkna den specifika energianvändningen i bruksskedet kommer ettenkelt beräkningsprogram, TMF-Energi 2.3, att användasDen nuvarande utformningen av huset Lipton har en specifik energianvändningpå 56,9 kWh/m2 år vilket är relativt lågt och nästan hälften av Boverketsenergikrav.Liptons energianvändning skall sänkas genom att:• Förbättra Um för Liptons klimatskal.• Avnända en dubbelskalsteknikHögskolan Dalarna• Planera Liptons placering för gynsamma yttre förhållanden.• Använda behovstyrd ventilation tillsammans med eleffektiva fläktar.De förbättringar som i första hand bör göras i huset Lipton är utformning avkonstruktionselementen och installation av ny teknik, så som behovstyrd- ocheleffektiv ventilation.

Abstract [en]

The Earth's climate is affecting all countries and Sweden is no exception. With agrowing global environmental problem everyone needs to contribute to change.The project's contribution to the environment is to show how energyconsumption of a multi-family apartment block can be reduced. By calculatingUm for the house Lipton's current building envelope and identify the parts whereimprovements could be made, and compile the elements of design which aremost promising for improving the building envelope. Technical measures witch isnot directly related to the building envelope, such as demand controlledventilation, electrically efficient fans and other energy-smart solutions will beutilized to reduce Lipton specific energy consumption.Buildings lose heat through the building envelope but by harnessing the sun'senergy, think carefully about the building's placement, increase insulationthickness and use smart ventilation solutions, the project aims to reduce thehouse Liptons specific energy consumption to at least half of Boverkets energydemands in 2014 for new buildings in climate zone 2 which is set to110 kWh/m2 year.To calculate the specific energy consumption in use phase, a simple calculationprogram, TMF-Energy 2.3, will be used. In the project, the heating system,water/sewer and use of household energy is not to be included.The original design of the house Lipton has a specific energy consumption of56.9 kWh/m2 year which is relatively low and almost half of Boverkets energyrequirementsThe energy consumption of Lipton will be decreased by:• Improving Um for Lipton's building envelope.• Using a double-shell technology.Högskolan Dalarna• Plan where the house is located for favorable outer conditions• Using demand-controlled ventilation with energy efficient fans

sted, utgiver, år, opplag, sider
2015.
HSV kategori
Identifikatorer
URN: urn:nbn:se:du-18715OAI: oai:DiVA.org:du-18715DiVA, id: diva2:840704
Tilgjengelig fra: 2015-07-09 Laget: 2015-07-09

Open Access i DiVA

Fulltekst mangler i DiVA

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric

urn-nbn
Totalt: 486 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf