CO2 emission evaluation of energy conserving measures in buildings connected to a district heating system: Case study of a multi-dwelling building in Sweden
Högskolan Dalarna, Akademin Industri och samhälle, Energiteknik.
2016 (Engelska)Ingår i: Energy, ISSN 0360-5442, E-ISSN 1873-6785, Vol. 111, s. 341-350Artikel i tidskrift (Refereegranskat) Published
Resurstyp
Text
Abstract [en]

When taking action to fulfill the directives from the European Union, energy conserving measures will be implemented in the building sector. If buildings are connected to district heating systems, a reduced heat demand will influence the electricity production if the reduced heat demand is covered by combined heat and power plants.This study analyze five different energy conserving measures in a multi-dwelling building regarding how they affect the marginal production units in the district heating system in Gävle, Sweden. For CO2 emission evaluations, two different combinations of heat and electricity conserving measures are compared to an installation of an exhaust air heat pump.The different energy conserving measures affect the district heating system in different ways. The results show that installing an exhaust air heat pump affects the use/production of electricity in the district heating system most and electricity conserving measures result in reduced use of electricity in the building, reduced use of electricity for production of heat in the district heating system and an increase of electricity production.The conclusion is that electricity use in the building is the most important factor to consider when energy conserving measures are introduced in buildings within the district heating system in Gävle.

Ort, förlag, år, upplaga, sidor
2016. Vol. 111, s. 341-350
Nyckelord [en]
District heating system; Energy efficiency; Greenhouse gases; Refurbishment; Simulation
Nationell ämneskategori
Energiteknik
Forskningsämne
Energi, skog och byggd miljö
Identifikatorer
URN: urn:nbn:se:du-21779DOI: 10.1016/j.energy.2016.05.002ISI: 000384776900029Scopus ID: 2-s2.0-84973177469OAI: oai:DiVA.org:du-21779DiVA, id: diva2:939791
Tillgänglig från: 2016-06-20 Skapad: 2016-06-20 Senast uppdaterad: 2017-11-28Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Personposter BETA

Rönnelid, Mats

Sök vidare i DiVA

Av författaren/redaktören
Rönnelid, Mats
Av organisationen
Energiteknik
I samma tidskrift
Energy
Energiteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 684 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf