Dalarna University's logo and link to the university's website

du.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
U-värde av isoleringsmaterial i en kassett: En experimentell jämförelse mellan en fönsterkassett som har isolering och en utan isolering
Dalarna University, School of Technology and Business Studies, Construction.
Dalarna University, School of Technology and Business Studies, Construction.
2016 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
U-value of insulation material in a cassette : An experimental comparative study of a window cassette with- and without isolation (English)
Abstract [sv]

Isolering och isoleringsmaterial är en av de viktigaste komponenterna i byggbranschen och har ett brett användningsområde och därför är efterfrågan stor. På grund av höga kostnader på marknaden, utförs nya och olika forskningar varje dag för att ta fram nya, alternativa isoleringsmaterial. Tekniken frambringar möjligheter att hitta och använda billigare material. Det är därför inte ovanligt att se isoleringar gjorda av flera olika material varje dag.

Syftet med detta examensarbete är att undersöka två Moniflexkassetter, en med isolering och en utan, i en klimatkammare, och för att sedan jämföra deras U- värden.

Resultatet visade isoleringens påverkan på kassetterna avsevärd. U-värdet blev lägre på den kassetten som hade isolering, vilket var ett bevis på att isoleringen kan användas som tilläggsisolering. Det gäller framförallt i fönster och glaspartier som har ett högt U-värde. Det vill säga att fönster och glaspartier inte behöver bytas ut mot nya fönster med lägre U-värden.

Företaget Isolights nuvarande U-värde för kassetten med isolering stämde inte överens med det testade U-värdet i Högskola Dalarnas klimatkammare. På kassetten utan isolering har det inte gjorts någon jämförelse mellan det testade värdet och företagets värde eftersom företaget saknar U-värde för detta.

Abstract [en]

Insulation and insulation material is one of the most important components in the construction industry and has a wide range of applications and therefore the demand is huge. Because of the high costs on the market, new and different researches take place every day to find alternative insulation materials. The technology make the opportunities greater to find and use cheaper materials. Therefore, it is not un common to see insulations made of different materials every day.

The purpose of this study is to investigate two Moniflexcassettes, one with insulation and one without, in a climate chamber, to then compare their u-values.

The results showed the influence on the insulation, that the u-value was lower on the cartridge with the insulation, and therefore a proof that the insulation can use as an additional insulation. This applied especially for windows and glass portions who have a high u-value, which mean that windows and glass portions do not have to change to newer windows with lower u-values.

The company Isolight´s current u-value of the cassette with the isolation was not the same as with the tested U-value in Högskolan Dalarnas climate chamber. On the cassette without insulation, there has been no comparison between the tested value and the value of the company because the company does not have a u-value for that.

Place, publisher, year, edition, pages
2016.
Keywords [en]
Cassette; U-value; climate chamber
Keywords [sv]
Kassett, U-värde; Klimatkammare
National Category
Construction Management
Identifiers
URN: urn:nbn:se:du-23928OAI: oai:DiVA.org:du-23928DiVA, id: diva2:1064024
Available from: 2017-01-11 Created: 2017-01-11

Open Access in DiVA

No full text in DiVA

By organisation
Construction
Construction Management

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 1436 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf