Dalarna University's logo and link to the university's website

du.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Experimental investigations of polymer hollow fibre integrated evaporative cooling system with the fibre bundles in a spindle shape
Dalarna University, School of Technology and Business Studies, Energy Technology.ORCID iD: 0000-0002-2369-0169
Show others and affiliations
2017 (English)In: Energy and Buildings, ISSN 0378-7788, E-ISSN 1872-6178, Vol. 154, p. 166-174Article in journal (Refereed) Published
Abstract [en]

Due to the advantages of light weight, corrosion resistant and low cost, hollow fibres have been studied as the substitute for metallic materials. A novel hollow fibre integrated evaporative cooling system, in which the hollow fibre module constitutes as the humidifier and the evaporative cooler, is proposed. This novel hollow fibre integrated evaporative cooling system will provide a comfortable indoor environment for hot and dry area. Moreover, the water vapour can permeate through the hollow fibre effectively, and the liquid water droplets will be prevented from mixing with the processed air. In order to avoid the flow channelling or shielding of adjacent fibres, the fibres inside each bundle were made into a spindle shape to allow maximum contact between the air stream and the fibre. The cooling performances of the proposed novel polymer hollow fibre integrated evaporative cooling system were experimentally investigated under the incoming air temperature in the range of 26 °C to 32 °C and relative humidity of 25%–35%. The effects of air velocities on the cooling effectiveness, heat and mass transfer coefficients, specific water consumption and pressure drop across the polymer hollow fibre module were analysed. Two sets of experimentally derived non-dimensional heat and mass transfer correlations were summarized, which could be favourable for the future design of polymer hollow fibre integrated evaporative cooling system.

Place, publisher, year, edition, pages
2017. Vol. 154, p. 166-174
Keywords [en]
Evaporative cooling, Experiment, Heat transfer, Mass transfer, Polymer hollow fibre
National Category
Energy Engineering
Research subject
Research Profiles 2009-2020, Energy and Built Environments
Identifiers
URN: urn:nbn:se:du-26295DOI: 10.1016/j.enbuild.2017.08.068ISI: 000413607400014Scopus ID: 2-s2.0-85028703256OAI: oai:DiVA.org:du-26295DiVA, id: diva2:1142097
Available from: 2017-09-18 Created: 2017-09-18 Last updated: 2021-11-12Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Zhang, Xingxing

Search in DiVA

By author/editor
Zhang, Xingxing
By organisation
Energy Technology
In the same journal
Energy and Buildings
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 229 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf