Kondensrisk i frånluftsfläkt för behovsstyrd ventilation: En experimentell undersökning
Dalarna University, School of Technology and Business Studies, Construction.
Dalarna University, School of Technology and Business Studies, Construction.
2018 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
Condensation in exhaust air fan for demandcontrolledventilation : An experimental study (English)
Abstract [sv]

I Sverige är det väldigt vanligt att villor och småhus har en oisolerad vind, en

kallvind. Genom att installera ett behovsstyrt frånluftssystem är ett sätt att

energieffektivisera både äldre hus och nybyggnationer. För att kunna placera en

frånluftsläkt på kallvinden i ett nordiskt klimat där temperaturer ner till -20 inte är

ovanligt behövs någon typ av isolering för att förhindra kondens att bildas i

aggregatet. Syftet med studien var att undersöka vid vilka temperaturer isolering

behövs och hur tjock isoleringen behöver vara för att undvika fuktutfällning i

aggregatet. En frånluftsfläkt, isolerade ledningsrör och en fuktig inomhusmiljö

installerades i klimatkammaren på Högskolan Dalarna för att utföra tester vid

olika temperaturer och olika isolering. Undersökningen visar att isolering behövs,

den visar vid vilka temperaturer och isolertjocklekar kondens kan förväntas och

vad som behövs för att undvika detta. Fuktproblem som skulle kunna uppstå i

samband med installation av ett behovsstyrt frånluftsystem kan tänkas

förebyggas med hjälp av resultaten i de här testerna.

Abstract [en]

In Sweden it is very common for villas and small houses to have an uninsulated

attic, a so called cold attic. Installing a demand-controlled ventilation system is a

way to increase energy efficiency in both old and newly built houses. To be able

to place an exhaust fan in a cold attic in a nordic climate, where temperatures

reaches twenty degrees below zero, some type of insulation is not uncommonly

required to prevent condensation from forming inside the unit. The purpose of

this study has been to investigate how thick the insulation needs to be around

the fan to prevent from condensation, depending on temperature. The

investigation have been done in the climate chamber at the university of

Dalarna. To ensure the right climate an exhaust fan with insulated conduits was

installed to create one damp indoor- and one colder outdoor environment to

conducted tests at different temperatures with different levels of insulation. The

study shows that insulation is required, at what temperatures and what levels of

insulation we can expect condensation to form and what is required to prevent

condensation from forming. The results from these tests could aid in preventing

moisture problems that could occur when installing a demand-controlled

ventilation system.

Place, publisher, year, edition, pages
2018.
Keywords [en]
Demand-controlled ventilation system, Condensation, Energy efficiency
Keywords [sv]
Behovsstyrd frånluftsfläkt; kondensrisk i frånluftsfläktar; nyckelord 3
National Category
Civil Engineering
Identifiers
URN: urn:nbn:se:du-27686OAI: oai:DiVA.org:du-27686DiVA, id: diva2:1206902
Available from: 2018-05-18 Created: 2018-05-18

Open Access in DiVA

No full text in DiVA

By organisation
Construction
Civil Engineering

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 242 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf