Jämförelse mellan energiberäkning med TMF Energi och IDA ICE -fallstudie för ett småhus
Dalarna University, School of Technology and Business Studies, Construction.
2018 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
Comparison of energy calculation with TMF Energy and IDA ICE, case study for a family house (English)
Abstract [sv]

För varje nyproducerat hus ska en energiberäkning tas fram i produktionsskedet och efter att byggnaden tagits i bruk ska en mätning ligga till grund för energideklarationen.

Detta görs för att krav ställs på energiförbrukningen i huset, för att målen till

år 2020 och 2050 ska nås.

Det finns många olika metoder för att beräkna energiförbrukningen, i den här rapporten kommer två energiberäkningsprogram jämföras och se på hur energianvändningen reagerar på solinstrålningen i de olika metoderna.

En handberäkning kommer göras för att validera om energianvändningsnivån är rimlig.

De två programmen är TMF Energi och IDA Indoor Climate and Energy (IDA ICE). Det huset beräkningarna är gjorda på är ett standardhus från husleverantören Fiskarhedenvillan.

Metoden går ut på att ha samma förutsättningar och indata i de olika metoderna så att resultaten går att jämföra och se hur de skiljer sig åt från varandra. Huset kommer placeras olika för att se hur orienteringen påverkar energiförbrukningen.

Resultaten för simuleringarna är nära varandra och handberäkning en avviker lite från programmen . Även om solfaktorer ändras i de olika datorprogrammen kan resultat matchas ihop för att bilda ett mönster.

Samma mönster kan ses i handberäkningen också men med större avvikelse.

Abstract [en]

For each newly produced house, an energy calculation will be made in the production state and after the building has started to be used, a measurement will form the basis for the energy declaration. This is done to make demands on the energy consumption of the house, in order to reach the targets by 2020 and 2050. There are many different methods for calculating energy consumption.

In this report, two energy calculation programs will be compared and look at how the energy usage responds to the solar radiation in the different methods. A hand calculation will be made to validate if the energy usage level is reasonable.

The two programs are TMF Energy and IDA Indoor Climate and Energy (IDA ICE). The calculations are made on a standard house from the house supplier Fiskarhedenvillan.

The method is based on having the same conditions and inputs in the different methods, so that the results can be compared and see how they differ from one another. The house will be placed differently to see how the orientation affects the energy consumption.

The results for the simulations are close to each other and the hand calculation differs from the programs. Even if solar factors change in the different computer programs, results can be matched to form a pattern.

The same patterns can be seen in the hand calculation, but with a greater deviation.

Place, publisher, year, edition, pages
2018.
Keywords [en]
Energy calculation 1; TMF Energy 2; IDA ICE 3
Keywords [sv]
Energiberäkning 1; TMF Energi 2; IDA ICE 3
National Category
Construction Management
Identifiers
URN: urn:nbn:se:du-28777OAI: oai:DiVA.org:du-28777DiVA, id: diva2:1257150
Available from: 2018-10-19 Created: 2018-10-19

Open Access in DiVA

No full text in DiVA

By organisation
Construction
Construction Management

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 297 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf