Uppföljning av fastighet med värmelager
Dalarna University, School of Technology and Business Studies, Energy Technology.
2019 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

Gamla byn AB är ett kommunalt fastighetsbolag i Avesta. 2015 byggdes en förskola vid namn Rödluvan i Horndal utanför Avesta, som en ny byggnad i Gamla byns fastighetsbestånd. Rödluvan försågs med ett relativt nytt värmesystem kallat ASES (Active Solar Energy Storage) vilket är en lösning som ägs av Norconsult. Värmesystemet är i huvudsak uppbyggt av ett värmelager under byggnaden, solfångare samt en värmepump. Solfångarna förser lagret med värme som sedan vid behov hämtas upp med hjälp av värmepumpen. Gamla byn vill ha en uppföljning av hur systemet har presterat för att kunna avgöra om ASES ska användas på fler av deras fastigheter. Under 2018 gjordes en energideklaration samt ett examensarbete vilka visade att värmesystemets energianvändning var mer än dubbelt så hög som det projekterade värdet. Det föregående examensarbetet presenterade åtgärdsförslag i form av optimering av ventilationen, vilket utförts efter detta. Även en ackumulatortank vilken ska balansera värmesystemet installerades under 2018, efter energideklarationen samt examensarbetet utfördes.

Det här examensarbetet är utfört som en kvantitativ fallstudie på förskolan Rödluvan på uppdrag av Gamla byn, då en ny uppföljning var av intresse. Mycket data har samlats in kring energianvändningen i fastigheten och det har under arbetets gång framkommit att värmesystemets energianvändning minskat avsevärt sedan våren 2018. Det här arbetet har även haft tillgång till mer information om mätvärdena än de tidigare undersökningarna och det har visat sig att en del korrigeringar har behövt göras på dessa för att få fram den verkliga energianvändningen av värmesystemet. Det tidigare examensarbetet samt energideklarationens värde till uppvärmning och varmvatten var 33 kWh/m2 , år jämfört med det projekterade värdet 15 kWh/m2 , år. Då energianvändningen minskat sedan de tidigare utredningarna samt korrigeringar gjorts på mätvärden har det framkommit att värmesystemets energianvändning är närmare det projekterade värdet. Medräknat en elpanna som endast varit vid i drift vid ett fåtal tillfällen då värmepumpen inte fungerat optimalt har energianvändningen sedan start 2015 enligt beräkningar i det här arbetet varit 26 kWh/m2 , år. Utesluts elpannan, då den inte driftsatts sedan åtgärderna under 2018, uppgår energianvändningen sedan start till 24 kWh/m2 , år. Kompletta mätningar har saknats för ett helt år sedan energianvändningen till värme och varmvatten minskat i fastigheten. Mätningar från den senaste vintern samt uppskattningar för återstående månader baserat på tidigare år, visar att energianvändningen det senaste året uppgått till ungefär 19 kWh/m2 , år. Med kompletta mätningar för ett helt år, samt vidare optimering av ventilationen, blir värdet troligen lägre. Slutsatsen är att värmesystemet tidigare inte verkar ha fungerat optimalt, men sedan de tidigare uppföljningarna under 2018 har energianvändningen minskat och det verkliga värdet ser ut att ligga i närheten av det projekterade. Detta förutsätter att värmesystemet fortsätter fungera minst lika bra som det har gjort den senaste tiden.

Abstract [en]

Gamla byn AB is a municipal housing-company in Avesta. In 2015 they built a nursery school named Rödluvan in Horndal outside of Avesta, as a new building in their property stock. Rödluvan was provided with a relatively new heating system named ASES (Active Solar Energy Storage) which is a solution by Norconsult. The heating system is mainly made up by a heat storage under the building, solar collectors and a heat pump. The solar collectors provides the storage with heat which is then collected by the heat pump when needed. Gamla byn wants an evaluation of how the system has performed so they can decide if ASES is to be used on additional buildings. During 2018 a thesis and an energy declaration was done, and they showed that the heating system used twice as much energy than was planned. They also presented action proposals in terms of optimization of the ventilation, which was later carried out by Gamla byn. A storage tank was also installed during 2018 to help balance the heating system. This was done after the thesis and energy declaration.

This thesis is executed as a quantitative case study on the nursery school Rödluvan, on order of Gamla byn, since a new evaluation was of interest. A lot of information has been collected on the energy use in the building and during the progress of the thesis it has emerged that the energy use has reduced considerably since spring 2018. This thesis has had access to a lot more information on the readings of the system compared to the previous evaluations and it has proved that some corrections has been needed on the readings to obtain the true energy use of the heating system. The energy declaration and the previous thesis showed that the value to heating and warmwater was 33 kWh/m2 , year, compared to the planned value of 15 kWh/m2 , year. Since the energy use has reduced considerably since they were written and some corrections has been done on the readings, the value in this work is closer to the planned value. Including energy use of an electric boiler, which has only been running a few times when the heat pump has not functioned properly, the energy use to heating and warmwater amounts to 26 kWh/m2 , year since 2015. If the electric boiler is excluded, considering that it has not been running since the energy use was reduced during 2018, the energy use to heating and warmwater has been 24 kWh/m2 , year since 2015. Complete readings are missing in order to measure the true energy use to heating and warmwater during one year since April 2018. Readings from the recent winter combined with estimations of the energy use during the remaining months based on values of previous years, it shows that the energy use the most recent year to heating and warmwater has been about 19 kWh/m2 , year. With complete readings for a whole year, combined with further optimization of the ventilation, the value probably reduces further. The conclusion is that the heating system doesn’t seem to have worked optimally, but since the previous evaluations in 2018 the energy use has reduced considerably, and the new value is much closer to the planned. This presumes that the heating system continues to function at least as well it has the recent year.

Place, publisher, year, edition, pages
2019.
Keywords [en]
Heat storage, energy use, heating system
Keywords [sv]
Värmelager, energianvändning, värmesystem
National Category
Energy Engineering
Identifiers
URN: urn:nbn:se:du-30549OAI: oai:DiVA.org:du-30549DiVA, id: diva2:1334742
Available from: 2019-07-03 Created: 2019-07-03

Open Access in DiVA

No full text in DiVA

By organisation
Energy Technology
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 398 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf