Response-surface-model-based system sizing for Nearly/Net zero energy buildings under uncertainty
City University of Hong Kong.
Show others and affiliations
2018 (English)In: Applied Energy, ISSN 0306-2619, E-ISSN 1872-9118, Vol. 228, p. 1020-1031Article in journal (Refereed) Published
Abstract [en]

Properly treating uncertainty is critical for robust system sizing of nearly/net zero energy buildings (ZEBs). To treat uncertainty, the conventional method conducts Monte Carlo simulations for thousands of possible design options, which inevitably leads to computation load that is heavy or even impossible to handle. In order to reduce the number of Monte Carlo simulations, this study proposes a response-surface-model-based system sizing method. The response surface models of design criteria (i.e., the annual energy match ratio, self-consumption ratio and initial investment) are established based on Monte Carlo simulations for 29 specific design points which are determined by Box-Behnken design. With the response surface models, the overall performances (i.e., the weighted performance of the design criteria) of all design options (i.e., sizing combinations of photovoltaic, wind turbine and electric storage) are evaluated, and the design option with the maximal overall performance is finally selected. Cases studies with 1331 design options have validated the proposed method for 10,000 randomly produced decision scenarios (i.e., users’ preferences to the design criteria). The results show that the established response surface models reasonably predict the design criteria with errors no greater than 3.5% at a cumulative probability of 95%. The proposed method reduces the number of Monte Carlos simulations by 97.8%, and robustly sorts out top 1.1% design options in expectation. With the largely reduced Monte Carlo simulations and high overall performance of the selected design option, the proposed method provides a practical and efficient means for system sizing of nearly/net ZEBs under uncertainty.

Place, publisher, year, edition, pages
2018. Vol. 228, p. 1020-1031
Keywords [en]
Response surface model, Monte Carlo simulation, System sizing, Zero energy building, Uncertainty
National Category
Building Technologies
Identifiers
URN: urn:nbn:se:du-30837DOI: 10.1016/j.apenergy.2018.06.156OAI: oai:DiVA.org:du-30837DiVA, id: diva2:1355749
Available from: 2019-09-30 Created: 2019-09-30 Last updated: 2019-10-01Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full texthttp://www.sciencedirect.com/science/article/pii/S0306261918310262

Authority records

Huang, Pei

Search in DiVA

By author/editor
Huang, Pei
In the same journal
Applied Energy
Building Technologies

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 26 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf