Dalarna University's logo and link to the university's website

du.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Validation of adverse events after hip arthroplasty: a Swedish multi-centre cohort study.
Karolinska Institutet.ORCID iD: 0000-0002-5090-0352
Show others and affiliations
2019 (English)In: BMJ Open, E-ISSN 2044-6055, Vol. 9, no 3, article id e023773Article in journal (Refereed) Published
Abstract [en]

OBJECTIVES: Preventing adverse events (AEs) after orthopaedic surgery is a field with great room for improvement. A Swedish instrument for measuring AEs after hip arthroplasty based on administrative data from the national patient register is used by both the Swedish Hip Arthroplasty Register and the Swedish Association of Local Authorities and Regions. It has never been validated and its accuracy is unknown. The aim of this study was to validate the instrument's ability to detect AEs, and to calculate the incidence of AEs following primary hip arthroplasties.

DESIGN: Retrospective cohort study using retrospective record review with Global Trigger Tool methodology in combination with register data.

SETTING: 24 different hospitals in four major regions of Sweden.

PARTICIPANTS: 2000 patients with either total or hemi-hip arthroplasty were recruited from the SHAR. We included both acute and elective patients.

PRIMARY AND SECONDARY OUTCOME MEASURES: The sensitivity and specificity of the instrument. Adjusted cumulative incidence and incidence rate.

RESULTS: The sensitivity for all identified AEs was 5.7% (95% CI: 4.9% to 6.7%) for 30 days and 14.8% (95% CI: 8.2 to 24.3) for 90 days, and the specificity was 95.2% (95% CI: 93.5% to 96.6%) for 30 days and 92.1% (95% CI: 89.9% to 93.8%) for 90 days. The adjusted cumulative incidence for all AEs was 28.4% (95% CI: 25.0% to 32.3%) for 30 days and 29.5% (95% CI: 26.0% to 33.8%) for 90 days. The incidence rate was 0.43 AEs per person-month (95% CI: 0.39 to 0.47).

CONCLUSIONS: The AE incidence was high, and most AEs occurred within the first 30 days. The instrument sensitivity for AEs was very low for both 30 and 90 days, but the specificity was high for both 30 and 90 days. The studied instrument is insufficient for valid measurements of AEs after hip arthroplasty.

Place, publisher, year, edition, pages
2019. Vol. 9, no 3, article id e023773
Keywords [en]
adverse events, global trigger tool, hip arthroplasty, orthopaedics, validation
National Category
Health Sciences
Identifiers
URN: urn:nbn:se:du-33969DOI: 10.1136/bmjopen-2018-023773PubMedID: 30850403OAI: oai:DiVA.org:du-33969DiVA, id: diva2:1441084
Part of project
Validering av registerdata för utvärdering av oönskade händelser efter höftproteskirurgiAvailable from: 2020-06-15 Created: 2020-06-15 Last updated: 2023-08-28Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMed

Authority records

Unbeck, Maria

Search in DiVA

By author/editor
Unbeck, Maria
In the same journal
BMJ Open
Health Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 35 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf