Dalarna University's logo and link to the university's website

du.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Measuring adverse events following hip arthroplasty surgery using administrative data without relying on ICD-codes.
(KIPS)ORCID iD: 0000-0002-5090-0352
Show others and affiliations
2020 (English)In: PLOS ONE, E-ISSN 1932-6203, Vol. 15, no 11, article id e0242008Article in journal (Refereed) Published
Abstract [en]

INTRODUCTION: Measure and monitor adverse events (AEs) following hip arthroplasty is challenging. The aim of this study was to create a model for measuring AEs after hip arthroplasty using administrative data, such as length of stay and readmissions, with equal or better precision than an ICD-code based model.

MATERIALS AND METHODS: This study included 1 998 patients operated with an acute or elective hip arthroplasty in a national multi-centre study. We collected AEs within 90 days following surgery with retrospective record review. Additional data came from the Swedish Hip Arthroplasty Register, the Swedish National Patient Register and the Swedish National Board of Health and Welfare. We made a 2:1 split of the data into a training and a holdout set. We used the training set to train different machine learning models to predict if a patient had sustained an AE or not. After training and cross-validation we tested the best performing model on the holdout-set. We compared the results with an established ICD-code based measure for AEs.

RESULTS: The best performing model was a logistic regression model with four natural age splines. The variables included in the model were as follows: length of stay at the orthopaedic department, discharge to acute care, age, number of readmissions and ED visits. The sensitivity and specificity for the new model was 23 and 90% for AE within 30 days, compared with 5 and 94% for the ICD-code based model. For AEs within 90 days the sensitivity and specificity were 31% and 89% compared with 16% and 92% for the ICD-code based model.

CONCLUSION: We conclude that a prediction model for AEs following hip arthroplasty surgery, relying on administrative data without ICD-codes is more accurate than a model based on ICD-codes.

Place, publisher, year, edition, pages
2020. Vol. 15, no 11, article id e0242008
National Category
Orthopaedics
Identifiers
URN: urn:nbn:se:du-35685DOI: 10.1371/journal.pone.0242008PubMedID: 33152055OAI: oai:DiVA.org:du-35685DiVA, id: diva2:1511526
Part of project
Validering av registerdata för utvärdering av oönskade händelser efter höftproteskirurgiAvailable from: 2020-12-18 Created: 2020-12-18 Last updated: 2023-01-19Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMed

Search in DiVA

By author/editor
Unbeck, Maria
In the same journal
PLOS ONE
Orthopaedics

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 32 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf