Air-to-water heat pump optimization with a photovoltaic system
Dalarna University, School of Information and Engineering.
2022 (English)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE creditsStudent thesis
Abstract [en]

Photovoltaic systems and heat pumps installations are increasing faster than ever before in Finland. Load regulation is becoming a hot topic in the PV market. With load regulation, the self-consumption can be increased, and the user may earn money. An air-to-water heat pump can be regulated with own produced electricity from a PV system by overheating the tank.

A typical single-family house of 150 m2 is simulated in Polysun for one year. The house has a photovoltaic system of 5.76 kW and an air-to-water heat pump with a tank of 180 l. The heat pump is used for space heating and domestic hot water. It is located in Helsinki, Finland. This work aims to compare two different control strategies for the heat pump.The first control strategy is based on the power output from the photovoltaic system and the second control strategy also takes the electricity consumption of the house into account. Both control strategies overcharge the tank with the heat pump to its maximum temperature of 65°C. Key figures such as self-consumption of photovoltaic system, annual electricity savings, payback time of regulation components and the performance of the heat pump are evaluated.

The investment of a control system for overcharging is economically feasible, and the selfconsumption of the photovoltaic system has been increased due to overcharging.Economical savings has been made annually and mostly during Summer. The performance of the heat pump has decreased slightly with overcharging.

Place, publisher, year, edition, pages
2022.
Keywords [en]
Photovoltaic, air-to-water heat pump, load regulation
National Category
Energy Systems
Identifiers
URN: urn:nbn:se:du-41858OAI: oai:DiVA.org:du-41858DiVA, id: diva2:1681891
Subject / course
Energy Technology
Available from: 2022-07-07 Created: 2022-07-07 Last updated: 2022-07-07

Open Access in DiVA

fulltext(1436 kB)857 downloads
File information
File name FULLTEXT01.pdfFile size 1436 kBChecksum SHA-512
4b504980604a8a5c26fd6a856eabe72a0ad9f661728af265831167465372445d7bb6fc8a34953d58597a9f3558874f24a25393e674afcb561b5afd5b306d2d48
Type fulltextMimetype application/pdf

By organisation
School of Information and Engineering
Energy Systems

Search outside of DiVA

GoogleGoogle Scholar
Total: 859 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 316 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf