EMISSIONS CHARACTERISTICS OF A RESIDENTIAL PELLET BOILER AND A STOVE
Dalarna University, School of Technology and Business Studies, Energy and Environmental Technology.ORCID iD: 0000-0002-4308-3980
Dalarna University, School of Technology and Business Studies, Energy and Environmental Technology.
2010 (English)In: World Bioenergy 2010, Jönköping Elmia, Sweden, 2010Conference paper, Published paper (Other academic)
Abstract [en]

Gaseous and particulate emissions from a residential pellet boiler and a stove are measured at a realistic 6-day operation sequence and during steady state operation. The aim is to characterize the emissions during each phase in order to identify when the major part of the emissions occur to enable actions for emission reduction where the savings can be highest. The characterized emissions comprised carbon monoxide (CO), nitrogen oxide (NO), total organic carbon (TOC) and particulate matter (PM 2.5). In this study, emissions were characterised by mass concentration and emissions during start-up and stop phases were also presented in accumulated mass. The influence of start-up and stop phases on the emissions, average emission factors for the boiler and stove were analysed using the measured data from a six-days test. The share of start-up and stop emissions are significant for CO and TOC contributing 95% and 89% respectively at the 20kW boiler and 82% and 89% respectively at the 12 kW stove. NO and particles emissions are shown to dominate during stationary operation.

Place, publisher, year, edition, pages
Jönköping Elmia, Sweden, 2010.
Keywords [en]
emissions, pellet boiler, stove, combustion, start-up, stop
Research subject
Energy and Built Environments, SWX-Energi, Integrerade system för sol och biobränsle
Identifiers
URN: urn:nbn:se:du-4865OAI: oai:dalea.du.se:4865DiVA, id: diva2:522150
Conference
World Bioenergy 2010 , Jönköping Elmia, Sweden, 25-27 May, 2010
Available from: 2010-06-29 Created: 2010-06-29 Last updated: 2021-11-12Bibliographically approved
In thesis
1. Emissions from realistic operation of residential wood pellets heating systems
Open this publication in new window or tab >>Emissions from realistic operation of residential wood pellets heating systems
2015 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Emissions from residential combustion appliances vary significantly depending on the firing behaviours and combustion conditions, in addition to combustion technologies and fuel quality. Although wood pellet combustion in residential heating boilers is efficient, the combustion conditions during start-up and stop phases are not optimal and produce significantly high emissions such as carbon monoxide and hydrocarbon from incomplete combustion. The emissions from the start-up and stop phases of the pellet boilers are not fully taken into account in test methods for ecolabels which primarily focus on emissions during operation on full load and part load.

The objective of the thesis is to investigate the emission characteristics during realistic operation of residential wood pellet boilers in order to identify when the major part of the annual emissions occur. Emissions from four residential wood pellet boilers were measured and characterized for three operating phases (start-up, steady and stop). Emissions from realistic operation of combined solar and wood pellet heating systems was continuously measured to investigate the influence of start-up and stop phases on total annual emissions. Measured emission data from the pellet devices were used to build an emission model to predict the annual emission factors from the dynamic operation of the heating system using the simulation software TRNSYS.

Start-up emissions are found to vary with ignition type, supply of air and fuel, and time to complete the phase. Stop emissions are influenced by fan operation characteristics and the cleaning routine. Start-up and stop phases under realistic operation conditions contribute 80 – 95% of annual carbon monoxide (CO) emission, 60 – 90% total hydrocarbon (TOC), 10 – 20% of nitrogen oxides (NO), and 30 – 40% particles emissions. Annual emission factors from realistic operation of tested residential heating system with a top fed wood pelt boiler can be between 190 and 400 mg/MJ for the CO emissions, between 60 and 95 mg/MJ for the NO, between 6 and 25 mg/MJ for the TOC, between 30 and 116 mg/MJ for the particulate matter and between 2x10-13 /MJ and 4x10-13 /MJ for the number of particles. If the boiler has the cleaning sequence with compressed air such as in boiler B2, annual CO emission factor can be up to 550 mg/MJ. Average CO, TOC and particles emissions under realistic annual condition were greater than the limits values of two eco labels. These results highlight the importance of start-up and stop phases in annual emission factors (especially CO and TOC). Since a large or dominating part of the annual emissions in real operation arise from the start-up and stop sequences, test methods required by the ecolabels should take these emissions into account. In this way it will encourage the boiler manufacturers to minimize annual emissions.

The annual emissions of residential pellet heating system can be reduced by optimizing the number of start-ups of the pellet boiler. It is possible to reduce up to 85% of the number of start-ups by optimizing the system design and its controller such as switching of the boiler pump after it stops, using two temperature sensors for boiler ON/OFF control, optimizing of the positions of the connections to the storage tank, increasing the mixing valve temperature in the boiler circuit and decreasing the pump flow rate. For 85 % reduction of start-ups, 75 % of CO and TOC emission factors were reduced while 13% increase in NO and 15 % increase in particle emissions was observed.

Place, publisher, year, edition, pages
Västerås: Mälardalen University, 2015
Series
Mälardalen University Press Dissertations, ISSN 1651-4238 ; 195
Keywords
Wood pellet, Heating, Combustion, boiler, stove, emissions, particulate matter
National Category
Bioenergy
Research subject
Energy and Built Environments, SWX-Energi, Integrerade system för sol och biobränsle
Identifiers
urn:nbn:se:du-20462 (URN)978-91-7485-246-2 (ISBN)
Public defence
2015-12-14, Clas Ohlson, Borlänge, 13:55 (English)
Opponent
Supervisors
Available from: 2015-12-21 Created: 2015-12-18 Last updated: 2021-11-12Bibliographically approved

Open Access in DiVA

fulltext(428 kB)1571 downloads
File information
File name FULLTEXT01.pdfFile size 428 kBChecksum SHA-512
f9188f179148220da5b59694ab76bb4d3eb8307f71eee05fa74633eb7618db1046e3d729f7a1845f55a46ecba40c1c6633b67ad9d8cc15888af2aa38bc0b7e55
Type fulltextMimetype application/pdf

Authority records

Win, Kaung Myat

Search in DiVA

By author/editor
Win, Kaung MyatPersson, Tomas
By organisation
Energy and Environmental Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 1572 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 1307 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf