Six-Day System Test and Component test and System Simulation for Combitanks with Internal heat Exchangers
Dalarna University, School of Technology and Business Studies, Environmental Engineering.
Dalarna University, School of Technology and Business Studies, Environmental Engineering.
1997 (English)Report (Other academic)
Abstract [en]

An international standard, ISO/DP 9459-4 has been proposed to establish a uniform standard of quality for small, factory-made solar heating systerns. In this proposal, system components are tested separatelyand total system performance is calculated using system simulations based on component model parameter values validated using the results from the component tests. Another approach is to test the whole system in operation under representative conditions, where the results can be used as a measure of the general system performance. The advantage of system testing of this form is that it is not dependent on simulations and the possible inaccuracies of the models. Its disadvantage is that it is restricted to the boundary conditions for the test. Component testing and system simulation is flexible, but requires an accurate and reliable simulation model. The heat store is a key component conceming system performance. Thus, this work focuses on the storage system consisting store, electrical auxiliary heater, heat exchangers and tempering valve. Four different storage system configurations with a volume of 750 litre were tested in an indoor system test using a six -day test sequence. A store component test and system simulation was carried out on one of the four configurations, applying the proposed standard for stores, ISO/DP 9459-4A. Three newly developed test sequences for intemalload side heat exchangers, not in the proposed ISO standard, were also carried out. The MULTIPORT store model was used for this work. This paper discusses the results of the indoor system test, the store component test, the validation of the store model parameter values and the system simulations.

Place, publisher, year, edition, pages
Högskolan Dalarna , 1997.
Series
SERC, ISSN 1401 - 7555 ; DU-SERC--61--SE
Identifiers
URN: urn:nbn:se:du-846OAI: oai:dalea.du.se:846DiVA, id: diva2:522737
Available from: 2005-01-12 Created: 2005-01-12 Last updated: 2012-04-24Bibliographically approved

Open Access in DiVA

fulltext(2573 kB)1113 downloads
File information
File name FULLTEXT01.pdfFile size 2573 kBChecksum SHA-512
77b9710864e1ece285995b97c3fb27868addb93f28aa9b2a22f1f859e7b1ffdd9a34bad23ea99b0ca06dffc28349957abca4add81d5ed8aeb6c894ac6dc61af6
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Bales, ChrisLorenz, Klaus
By organisation
Environmental Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 1113 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 1474 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf