Dalarna University's logo and link to the university's website

du.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Fuktutredning av massivträkonstruktion: Analys av vägg utan ångspärr
Dalarna University, School of Technology and Business Studies, Construction.
Dalarna University, School of Technology and Business Studies, Construction.
2014 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
Moisture analysis of solid wood construction : Analysis of a wall without vapour barrier (English)
Abstract [sv]

Rapporten ingår i ett FoU- projekt för Högskolan Dalarna, där målet är att ta fram en konstruktion utan ångspärr som ska klara dagens mått på lufttäthet och fuktkrav.

Syftet med denna rapport är att utreda hur fukt påverkar en byggnad medmassivträstomme och olika isoleringsmaterial utan ångspärr. Mineralull och träfiberisolering jämförs mot varandra för att se hur dessa påverkarfuktbelastningen i en väggkonstruktion. Testobjektet är lokaliserat i Dalarna, inget fukttillskott har funnits inomhus i byggnaden.

För att genomföra detta arbete har tre stycken olika metoder används. Ensimulering, verkliga uppmätta värden och en provtagning. Fuktsimuleringen genomfördes med hjälp av programmet WUFI, uppmätta värden i form av relativ fuktighet och temperatur har samlats in kontinuerligt under två års tid från väggkonstruktionen via mätsensorer. Provtagningen utfördes med ett fysiskt ingrepp på samma nivå i konstruktionen som mätsensorer var placerade.

Resultat presenteras i form av diagram och tabeller där det går att avläsa konstruktionens nulägesstatus i form av relativ fuktighet, temperatur, fuktkvot och mikrobiologisk påväxt. Isoleringsmaterialen påvisar en hög relativ fuktighet under vinterhalvåret längst ut i konstruktionen mot utomhusklimatet. Utomhusklimatet har visats spela stor roll i detta. Ingen direkt mikrobiologisk påväxt har påträffats trots en hög halt av fukt.

Resultaten visar att träfiberisoleringen har bättre förmåga att hantera fukt i jämförelse med mineralullen. En vidarestudie med fuktbelastning och 21 °C inomhus bör utföras. Men för att denna studie ska fungera rekommenderas en tvåstegstätad fasadlösning för att klara fuktbelastningen i väggkonstruktionen.

Abstract [en]

The report is part of a research and development project for Dalarna University,where the goal is to produce a design without a vapour barrier that will meettoday's measure of airtightness and moisture requirements.

The purpose of this report is to investigate how moisture affects a building withsolid wood and various insulation materials without vapour barrier. Mineral woolinsulation and wood fiber insulation will be compared against each other to seehow they affect the moisture load in a wall. The test object is located in Dalarna,no additional moisture load affect the indoor environment.

To carry out this work, three different methods are used. A moisture simulationwas performed using the program WUFI, measured values in terms of relativehumidity and temperature were collected over two years from the wall of thebuilding. A sampling was performed with a physical operation on the same levelin the wall where measurement sensors were placed.

Results are presented in form of graphs and tables where you can read thecurrent state of the construction in terms of relative humidity, temperature,moisture content and microbiological fouling. Insulation materials demonstrate ahigh relative humidity at outer layers of the construction during the wintermonths. The external environment has been shown to play a major part for theresults. No direct microbiological fouling has been detected despite a highcontent of moisture.

The result of wood fiber insulation demonstrates a better ability to handlemoisture. A further study with a moisture load and 21 degrees indoors should beperformed. But for this study to work it’s recommended to change the currentfacade solution to a two- step sealed facade solution to manage the moistureload in the wall.

Place, publisher, year, edition, pages
2014.
Keywords [en]
Moisture; Solid wood; Vapour barrier
Keywords [sv]
Fukt; Massivträ; Ångspärr
National Category
Construction Management
Identifiers
URN: urn:nbn:se:du-14628OAI: oai:DiVA.org:du-14628DiVA, id: diva2:732034
Available from: 2014-07-03 Created: 2014-07-03 Last updated: 2015-04-14Bibliographically approved

Open Access in DiVA

fulltext(6490 kB)1868 downloads
File information
File name FULLTEXT01.pdfFile size 6490 kBChecksum SHA-512
a5a33712354f50ca58db1eac4a8756c1c0b00467ade59f87ecc17159e7d17819e80f233dd04d44b1dd63216600e501a3815132b69a6bd0ba2c40c2433f930aa8
Type fulltextMimetype application/pdf

By organisation
Construction
Construction Management

Search outside of DiVA

GoogleGoogle Scholar
Total: 1870 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 2359 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf