Dalarna University's logo and link to the university's website

du.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
The Moxus Modular metabolic sustem evaluated with two sensors for ventilation against the Douglas bag method
Gymnastik- och idrottshögskolan, GIH, Laboratoriet för biomekanik och motorisk kontroll (BMC).
Gymnastik- och idrottshögskolan, GIH, Laboratoriet för tillämpad idrottsvetenskap (LTIV).
Gymnastik- och idrottshögskolan, GIH, Laboratoriet för biomekanik och motorisk kontroll (BMC).
2013 (English)In: European Journal of Applied Physiology, ISSN 1439-6319, E-ISSN 1439-6327, Vol. 113, no 5, p. 1353-1367Article in journal (Refereed) Published
Abstract [en]

This study evaluated the Moxus metabolic system with the Douglas bag method (DBM) as criterion. Reliability and validity were investigated in a wide range of ventilation and oxygen uptake and two sensors for determining ventilation were included. Thirteen well-trained athletes participated in one pre-test and four tests for data collection, exercising on a cycle ergometer at five submaximal powers (50-263 W) and at [Formula: see text]. Gas exchange variables were measured simultaneously using a serial setup with data collected on different days in an order randomized between Moxus with pneumotachometer (MP) and turbine flowmeter (MT) sensors for ventilation. Reliability with both sensors was comparable to the DBM. Average CV (%) of all exercise intensities were with MP: 3.0 ± 1.3 for VO(2), 3.8 ± 1.5 for VCO(2), 3.1 ± 1.2 for the respiratory exchange ratio (RER) and 4.2 ± 0.8 for V (E). The corresponding values with MT were: 2.7 ± 0.3 for VO(2), 4.7 ± 0.4 for VCO(2), 3.3 ± 0.9 for RER and 4.8 ± 1.4 for V (E). Validity was acceptable except for small differences related to the determination of ventilation. The relative differences in relation to DBM at the powers including [Formula: see text] were similar for both sensors with the ranges being: +4 to -2 % for V (E), +5 to -3 % for VO(2) and +5 to -4 % for VCO(2) while RER did not differ at any power. The Moxus metabolic system shows high and adequate reliability and reasonable validity over a wide measurement range. At a few exercise levels, V (E) differed slightly from DBM, resulting in concomitant changes in VO(2) and VCO(2).

Place, publisher, year, edition, pages
Springer, 2013. Vol. 113, no 5, p. 1353-1367
Keywords [en]
Moxus Modular metabolic system; Douglas bag method; Validity; Reliability; Turbine flowmeter; Pneumotachometer; Oxygen uptake; Carbon dioxide production; Ventilation; Respiratory exchange ratio
National Category
Biological Sciences
Identifiers
URN: urn:nbn:se:du-15634DOI: 10.1007/s00421-012-2551-1ISI: 000317627700025PubMedID: 23224357OAI: oai:DiVA.org:du-15634DiVA, id: diva2:747734
Available from: 2013-01-04 Created: 2014-09-16 Last updated: 2017-12-05Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMed

Search in DiVA

By author/editor
Nilsson, Johnny
In the same journal
European Journal of Applied Physiology
Biological Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 415 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf