Luftläckningens inverkan på energiåtgången i byggnader med väggar av massivträ utan fuktspärr
Dalarna University, School of Technology and Business Studies, Construction.
Dalarna University, School of Technology and Business Studies, Construction.
2015 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
The air tightness effect on energy use in buildings with massive wood walls without moisture barrier (English)
Abstract [sv]

Under utbildningen till byggingenjörer har författarna funnit engagemang i utvecklandet av energi- och klimatsmarta småhus. I flertalet kurser har diskussion förts kring hur det kan gå att spara på naturens resurser genom att minska energiförbrukningen. För att uppnå detta byggs hus som är lufttäta där värme förhindras att läcka ut ur byggnaden. Ett exempel på ett sådant hus är ett så kallat "Passivhus".

Högskolan Dalarna har sedan 2013 utfört ett forskningsprojekt där en byggnad benämnd "Forskningskuben" uppförts om 15 m2 som ett Passivhus med massivträstomme utan plastbaserad fuktspärr. Regelbundna mätningar har tagits på luftläckningen i 24 månader och resultatet av dessa mätningar indikerar på en systematisk variation i luftläckningen över året.

I detta examensarbete undersöks hur den årliga variationen av luftläckningen i en byggnad påverkar energibehovet i en byggnad utan plastbaserad fuktspärr. Vidare undersöks energiprestanda samt hur den uppmäta luftläckningen i "Forskningskuben" teoretiskt förändras om motsvarande byggsystem skulle användas för en 120 m2 fiktiv byggnad. Detta med hjälp av mätningarna som togs under 24 månader i kuben.

Resultat i undersökningen är att den årliga variationen av luftläckningen knappt påverkar den fiktiva byggnadens energiprestanda trots att den varierar mellan 0,15 - 0,20 l/sm2.

Abstract [en]

During the training to become building engineers the writers of this essay have been committed to the development of energy and climate smart houses. In several courses there have been discussions on how to save nature's resources by decreasing the consumption of energy. In order to achieve this, houses which are air tight so that the warmth is prevented from leaking out of the building, are being built. An example of such a house is a "Passive House".

Högskolan Dalarna has since 2013 carried out a research project where a building with the measurement 15 m2, named the "Test Cube", has been erected as a Passive House with a frame of massive wood without a plastic based moisture barrier. Measurements of the air tightness have been performed regularly over 24 months and the result of these measurements indicates a systematic variety of the air tightness over the year.

In this essay the authors are examining how the yearly variety of a building's air tightness affects the energy need in a building without a plastic based moisture barrier. Furthermore are the authors examining the energy performance as well as how the measured air tightness in the "Test Cube" theoretically will change if a corresponding building system will be used in a 120 m2 fictitious building. This is done with the help of the measurements done over the 24 months in the "Test Cube".

The result of these investigations is that the yearly variety of air tightness barely affects the energy performance of the fictitious building despite the air tightness varying between 0,15-0,20 l/sm2.

Place, publisher, year, edition, pages
2015.
Keywords [en]
cross laminated timber; passive house; Airtightness, air seepage
Keywords [sv]
Massivträ, Passivhus, luftläckning, luftläckage
National Category
Construction Management
Identifiers
URN: urn:nbn:se:du-20821OAI: oai:DiVA.org:du-20821DiVA, id: diva2:896171
Available from: 2016-01-20 Created: 2016-01-20

Open Access in DiVA

No full text in DiVA

By organisation
Construction
Construction Management

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 429 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf