Performance Analysis of a Grid-Connected PV System in Borlänge, Sweden
Högskolan Dalarna, Akademin Industri och samhälle, Energi och miljöteknik.
2014 (engelsk)Independent thesis Advanced level (degree of Master (One Year)), 10 poäng / 15 hpOppgave
Abstract [en]

This thesis aimed to evaluate the performance of the new configuration of the array one of Högskolan Dalarna grid-connected PV system. This PV grid-connected system has been in operation since 1994. The system is composed of two arrays with a rated power of 1.62kW and two inverters of 1.2 kWp. In 2014 the new configuration of array one was composed of 4 strings of 9 modules each. This configuration had twice as much current than array two, and its voltage was halved (180V). The objective was to improve the global performance of the system, mostly under low irradiance conditions. The performance evaluation of the system was conducted according to IEC 61724 standard, and was performed in March and April 2014.

It appeared that the higher current in array one improved the turn-on power of its inverter. While the inverter of array two started operating at 126W/m² the inverter of array one started at 37W/m². It was also shown that the array yield of array one increased by 1% at low irradiance (0-200W/m²) during the two months of this thesis work. Moreover, the input voltage dependency of the inverter was clearly shown. Halved the voltage in array one increased the inverter efficiency between 1% and 2%. It was shown that the higher current of the array one did not impact the losses of the system. The system losses also decreased between 9.4% and 10.5%. Besides, this work highlighted that arrays’ DC power was probably different. It led to a better performance of array two at high irradiance compare to array one. Eventually the performance ratio of array one was greater than array two during these two months. It reached 63.2% in March and 69.4% in April.

sted, utgiver, år, opplag, sider
2014.
HSV kategori
Identifikatorer
URN: urn:nbn:se:du-14648OAI: oai:DiVA.org:du-14648DiVA, id: diva2:732252
Tilgjengelig fra: 2014-07-03 Laget: 2014-07-03 Sist oppdatert: 2025-10-09bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric

urn-nbn
Totalt: 1182 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf