Dalarna University's logo and link to the university's website

du.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Prestandaanalys vid rengöring av värmeväxlare i fjärrvärmecentral för småhus: Fallstudie på rengöring av en värmeväxlare för småhus
Dalarna University, School of Technology and Business Studies, Energy Technology.
Dalarna University, School of Technology and Business Studies, Energy Technology.
2020 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
: Case study on cleaning a residential heat exchanger (English)
Abstract [sv]

Försmutsning av plattvärmeväxlare i fjärrvärmecentraler minskar avkylningen av det cirkulerande vattnet i fjärrvärmenätet. Detta ökar behovet av värmeproduktion i fjärrvärmeverket vilket medför ökade utsläpp av växthusgaser. Mängden försmutsning beror på vattnets kvalitet och material i systemet. I denna studie undersöks prestandaförändring av värmeväxlare i fjärrvärmecentraler för småhus före och efter rengöring samt för en ny värmeväxlare. Prestandan mäts i laboratorium genom att mäta temperaturer på in- och utlopp på värmeväxlaren vid bestämda flöden. Utvärderingen inkluderar prestandaförändring för UA-värdet, Temperaturverkningsgrad, Effektivitet NTU och möjlig påverkan på växthusgasutsläpp från Borlänge Energis fjärrvärmesystem. En osäkerhetsanalys genomfördes för att bestämma de teoretiska osäkerheterna.Resultaten från studien visar att rengöring av småhusvärmeväxlare med CIP-metoden har en viss effekt på både tappvattenvärmeväxlaren och värmeväxlaren. För värmeväxlaren är förändringen liten där ökningen på UA-värdet ligger mellan 10–202 W/˚C jämfört med tappvattenvärmeväxlaren där det ligger mellan 205–870 W/˚C. Störst effekt har rengöringen på tappvattenvärmeväxlaren vid högre flöde. Värmeöverföringen är likvärdig för en ny värmeväxlare och den rengjorda.En sänkt returtemperatur från fjärrvärmecentraler leder till en förbättrad verkningsgrad på fjärrvärmeverket som bidrar till en minskning av mängden växthusgasutsläpp. Enligt de resultat och beräkningar utförda i studien kan genom rengöring returtemperaturen minskas med 2,3 ˚C ±0,4 % från fjärrvärmecentralerna i småhus till Borlänge Energis fjärrvärmenät.Rengöring av tappvattenvärmeväxlare kan vara ett alternativ till att byta ut mot en ny för småhusägaren, med förutsättning att priset för rengöring är lägre än att köpa en ny och att fjärrvärmesystemet har flödesavgift. Detta gäller dock inte värmeväxlaren för värme där skillnaden i värmeöverföring mellan en smutsig och ny eller rengjord är marginell.

Abstract [en]

Fouling of plate heat exchangers in district heating substations reduces the cooling of circulating water in the district heating network. This increases energy production at the district heating plant, which results in increased greenhouse gas emissions. The amount of fouling depends on the quality of the water and material in the system. This study evaluates the performance change of heat exchangers in district heating substations for residential housing before and after cleaning, and new heat exchangers. Performance is measured in the laboratory by measuring temperatures before and after cleaning at specified flows. The evaluation includes performance change of UA-value, Temperature efficiency, Effectiveness NTU and possible impact on greenhouse gas emissions from Borlänge Energi's district heating system.The results of the study show that cleaning of residential heat exchangers with the CIP method has a certain effect on both the tap water heat exchanger and the heat exchanger. For the heat exchanger, the improvement in performance is small where the UA-value increases between 10-202 W/˚C compared to the tap water heat exchanger where it is between 205-870 W/˚C. The highest effect is the cleaning on the tap water heat exchanger at higher flow. The heat transfer is equivalent for a new heat exchanger and the cleaned one.Reduced return temperature from the district heating network leads to an improved efficiency at the district heating plant, which contributes to a reduction in the amount of greenhouse gas emissions. According to the results and calculations performed in the study, by cleaning the return temperature can be reduced by 2,3 ˚C ± 0.4% from the district heating substations in residential houses to Borlänge Energy's district heating network.Cleaning of tap water heat exchangers can be an alternative to switching to a new one for the homeowner, provided that the price for cleaning is lower than buying a new one and that the district heating system has flow rate tariff. However, this does not apply to the heat exchanger where the difference in heat transfer between one with fouling and a new or cleaned is marginal.

Place, publisher, year, edition, pages
2020.
Keywords [en]
Heat Exchanger, Cleaning of Heat Exchanger, District Heating, CIP, Return Temperature, Supply Temperature
Keywords [sv]
Värmeväxlare, Rengöring av Värmeväxlare, Fjärrvärme, CIP, Returtemperatur, Framledningstemperatur
National Category
Energy Engineering
Identifiers
URN: urn:nbn:se:du-34465OAI: oai:DiVA.org:du-34465DiVA, id: diva2:1451363
Available from: 2020-07-02 Created: 2020-07-02 Last updated: 2025-10-09

Open Access in DiVA

fulltext(2347 kB)1689 downloads
File information
File name FULLTEXT01.pdfFile size 2347 kBChecksum SHA-512
376d0da10a4ab036389f7d951ac4ddeb7ca9970f90fd5fc37ac5087e3a36d7bbb8b844cfd6f74c455efc0990a2255e94e405001f24d4d07b5c5f9041b83cae96
Type fulltextMimetype application/pdf

By organisation
Energy Technology
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 1690 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 771 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf