Dalarna University's logo and link to the university's website

du.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Total body weight estimation by 3D camera systems: Potential high‐tech solutions for emergency medicine applications? A scoping review
Department of Emergency Medicine, Schmidt College of Medicine, Florida Atlantic University, Boca Raton, Florida, USA, US.ORCID iD: 0000-0002-4520-2007
Department of Emergency Medicine, Schmidt College of Medicine, Florida Atlantic University, Boca Raton, Florida, USA, US.
Department of Biomedical Engineering, Florida International University, Miami, Florida, USA, US.
Department of Emergency Medicine, Schmidt College of Medicine, Florida Atlantic University, Boca Raton, Florida, USA, US.
Show others and affiliations
2024 (English)In: Journal of the American College of Emergency Physicians Open, ISSN 2688-1152, Vol. 5, no 5Article, review/survey (Refereed) Published
Abstract [en]

Background Weight estimation is required in adult patients when weight-based medication must be administered during emergency care, as measuring weight is often not possible. Inaccurate estimations may lead to inaccurate drug dosing, which may cause patient harm. High-tech 3D camera systems driven by artificial intelligence might be the solution to this problem. The aim of this review was to describe and evaluate the published literature on 3D camera weight estimation methods.

Methods A systematic literature search was performed for articles that studied the use of 3D camera systems for weight estimation in adults. Data on the study characteristics, the quality of the studies, the 3D camera methods evaluated, and the accuracy of the systems were extracted and evaluated.

Results A total of 14 studies were included, published from 2012 to 2024. Most studies used Microsoft Kinect cameras, with various analytical approaches to weight estimation. The 3D camera systems often achieved a P10 of 90% (90% of estimates within 10% of actual weight), with all systems exceeding a P10 of 78%. The studies highlighted a significant potential for 3D camera systems to be suitable for use in emergency care.

Conclusion The 3D camera systems offer a promising method for weight estimation in emergency settings, potentially improving drug dosing accuracy and patient safety. Weight estimates were satisfactorily accurate, often exceeding the reported accuracy of existing weight estimation methods. Importantly, 3D camera systems possess characteristics that could make them very appropriate for use during emergency care. Future research should focus on developing and validating this methodology in larger studies with true external and clinical validation.

Place, publisher, year, edition, pages
2024. Vol. 5, no 5
Keywords [en]
3D camera weight estimation, drug dosing, weight estimation
National Category
Health Sciences General Practice
Identifiers
URN: urn:nbn:se:du-49896DOI: 10.1002/emp2.13320OAI: oai:DiVA.org:du-49896DiVA, id: diva2:1923518
Available from: 2024-12-27 Created: 2024-12-27 Last updated: 2025-10-09Bibliographically approved

Open Access in DiVA

fulltext(495 kB)115 downloads
File information
File name FULLTEXT01.pdfFile size 495 kBChecksum SHA-512
fd97650aed5eb11d0dc763198d1e50e06de85ae5e0810ae75fd0a00226e38446e73f5534dc45fb44f4bda052dc61fc463f81f8dbeb55aa7ff21fa6b2e6164ab6
Type fulltextMimetype application/pdf

Other links

Publisher's full text

Authority records

Engström, Gabriella

Search in DiVA

By author/editor
Wells, MikeEngström, Gabriella
Health SciencesGeneral Practice

Search outside of DiVA

GoogleGoogle Scholar
Total: 117 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 361 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • chicago-author-date
  • chicago-note-bibliography
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf